摘要
总结了河北盛华化工有限公司离子膜烧碱项目电气系统的建设情况,讨论了热电厂的基本运行数据、电解设备对整流设备参数的要求、整流器的特点及运行状况,提出了建设新项目应注意的问题。
The construction situation about the electric system of ion - exchange membrane project in Hebei Shenghua Chemical Industry Co. , Ltd. is summarized. The basic running data of heat and power plant and the demands of electrolysis devices on the parameters of current rectifier are discussed , as well as the characteristics and the running state of rectifiers. The points for attention are suggested about constructing new projects.
出处
《氯碱工业》
CAS
2006年第5期10-12,18,共4页
Chlor-Alkali Industry
关键词
离子膜法烧碱
电气系统
整流装置
ion - exchange membrane caustic soda
electric system
current rectifier