摘要 目的:研究骨导听性脑干反应(ABR)的波形特点及正常的气、骨导ABRⅤ波潜伏期-强度曲线及相应的反应阈值,为临床气导ABR(AC-ABR)和骨导ABR(BC-ABR)的联合应用提供参考依据。方法:利用Nicolet-spirit型诱发电位仪、EAR-3A插入式耳机和Radioear B-71骨振动器对一组听力正常年轻人(男32耳、女24耳)进行短声气骨导ABR测试,并观察对侧给予白噪声掩蔽对BC-ABR阈值及潜伏期的影响。结果:气骨导ABR相应强度下波形相似波Ⅴ潜伏期-强度曲线表明,随着刺激强度逐渐减低,潜伏期逐渐延长。骨导Click的潜伏期要比气导Click潜伏期延长的程度大,BC-ABR反应阈比气导ABR高。对侧70 dBSPL以下强度宽带噪声的使用对BC-ABR阈值及阈上10 dB强度下波Ⅴ潜伏期均无显著影响(P>0.05)。结论:(1)BC-ABR波形特点与相应刺激强度的AC-ABR极为相似。BC-ABR与AC-ABR潜伏期-强度函数曲线可望联合用于传导障碍及其程度的评估;(2)骨导行为的听阈水平超过40 dBHL时,BC-ABR难以引出,对其结果的解释应持慎重态度;(3)骨导ABR测试时常规加对侧噪声掩蔽,但掩蔽声强度不应超过60 dB。 Objective: To observe normative auditory brainstem response (ABR) latency-intensity functions and the threshold and provide reference for combined clinical use of air- and bone-conducted ABR. Methods: ABR absolute thresholds and latencies( Ⅴ waves)were obtained from 56 ears of 28 young persons with normal hearing using both the EARTONE insert earphone and the Radioear B-71 bone viboratory. Results: The air- and bone-conducted wave Ⅴ latency-intensity functions exhibited increased latencies as intensity decreased. The bone-conducted clicks yielded somewhat longer latencies than the air-conducted ones. Conclusions : ( 1 ) The waves of air- and boneconducted ABR are similar, and more information on ascertaining the presence and magnitude of a conductive hearing loss can be obtained when both air- and bone-conducted ABR wave Ⅴ latency-intensity functions are administered. (2) When the threshold of bone-conducted hearing exceeds approximately to 40 dBHL, no BC-ABR responses can be observed. (3) Masking is often necessary when administering bone-conducted ABR test, but intensity of masking should not exceed to over 60 dBSPL.
出处 《山东大学耳鼻喉眼学报》 CAS 2006年第1期9-13,共5页 Journal of Otolaryngology and Ophthalmology of Shandong University
关键词 听性脑干诱发反应 知觉掩蔽 骨振器 Auditory brain stem evoked response Perceptual masking Bone viborator
  • 相关文献

参考文献11

  • 1Joint committee on infant heating. Year 2000 position statement:principles and guidelines for early hearing detection and intervention programs [S]. Am J Audio,2000, 9: 9.
  • 2戚以胜.小儿电反应测听的临床应用策略[M].北京:北京医科大学、中国协和医科大学联合出版社,1993.35-38.
  • 3Yang EY, Stuart A, Mencher GT, et al. Auditory brainstem reponses to air and bone-conducted clicks in the audiological assessment of at risk infants [J]. Ear Hear,1993, 14: 175.
  • 4Hall JW. Bone-conduction ABR: clinically feasible and clinically valuable[J]. The Hearing, 1994, 47 : 10.
  • 5殷善开,武文明,顾瑞,姜泗长,陈洪文,于黎明.听性脑干反应骨导刺激声的声学特性[J].听力学及言语疾病杂志,1999,7(1):13-16. 被引量:6
  • 6Cone-Wesson B, Ramirez G M. Heaing sensitivity in newbons estimated from ABRs to bone-conducted sounds[J]. Jam Audiol, 1997, 8: 299-307.
  • 7王国新,倪道凤,李奉荣,张志勇.骨导听性脑干反应影响因素的研究[J].临床耳鼻咽喉科杂志,2002,16(4):150-152. 被引量:9
  • 8Nousak JMK, Stapells DR. Frequency specificity of the auditory brainstem response to bone conducted tones in infants and adults[J]. Ear Hear, 1992, 12: 87.
  • 9Foxe JJ, Stapells DR. Normal infant and adult auditory brainstem responses to bone-conducted tones[J]. Audiology, 1993, 32: 95.
  • 10Stuart A, Yang EY, Stenstrom R, et al. Auditory brainstem response thresholds to air and bone-conducted clicks in neonates and adults[J]. Am J Otol, 1993, 14: 176.

二级参考文献4

  • 1Cone-Wesson B,Ramirez G M.Hearing sensitivity in newboms estimated from ABRs to bone-conducted sounds.J Am Audiol,1997,8:299-307.
  • 2Freeman S,Sichel J Y,Sohmer H.Bone conduction experiments in animals-evidence for a non-osseous mechanism.Hear Res,2000,146:72-80.
  • 3Sohmer H,Freeman S.The latency of auditory nerve brainstem evoked responses to air-and bone-conducted stimuli.Hear Res,2001,160:111-113.
  • 4何永照,姜泗长主编.耳鼻咽喉科全书.耳科学(上).上海:上海科学技术出版社,1982.88-90.

共引文献13

同被引文献47

引证文献6

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部