期刊文献+

微流动注射芯片化学发光法检测鱼虾中的四环素 被引量:13

Determination of Tetracycline in Fish and Shrimp by Chemiluminescence Micro-flow Injection on a Chip
下载PDF
导出
摘要 在微流动注射芯片上设计了螺旋形流通池,并采用精确时间控制进样方式,结合四环素(TC)对鲁米诺-H2O2化学发光体系的抑制作用,建立了微流动注射芯片化学发光法测定鱼虾中四环素的新方法。该系统中螺旋形反应池由激光雕刻机在聚甲基丙烯酸甲酯(PMMA,50×40×3mm)上雕刻而成。在实验所建立的最佳条件下,该方法在2.0×10^-7~1.0×10^-5g/mL范围内化学发光的降低值与四环素的质量浓度具有好的线性关系.检出限为1.7×10^-8g/mL。相对标准偏差为1.7%(n=11,p=5.0×10^-7g/mL),检测结果满意。 A micro-flow injection system on a chip was prepared for the determination of tetracycline in fish and shrimp, based on luminol- H2O2 chemilunlineseence. Spiral flow cell channels were fabricated using laser on poly( methyl methacrylate) (PMMA). The sampling time was controlled precisely by atimer, The linear range was 2.0×10^-7~1.0×10^-5g/mL with a detection limit of 1.7×10^-8g g/mL, and the relative standard deviation was 1.7% ( n =11, p = 5.0 ×10^-7 g/mL), The method is simple, rapid and highly sensitive and consumes less reagent, The proposed method has been successfully applied to the determination of tetracycline in fish and shrimp,
出处 《分析测试学报》 CAS CSCD 北大核心 2006年第3期83-85,共3页 Journal of Instrumental Analysis
基金 科技部重大专项(2003BA301A20)
关键词 微流动注射 芯片 化学发光 四环素 食品安全 Microflow injection Chip Chemiluminescence Tetracycline Food safety
  • 相关文献

参考文献8

  • 1SANTOS M D F,VERMEERSCH H,REMON J P,et al.Validation of a high performance liquid chromatographic method for the determination of tetracycline [ J ].B-Biomedicao Applications,1996,628 (2):301-308.
  • 2王蕾,徐智秀,张孝松,邵学广.反相高效液相色谱法快速测定7种四环素类抗生素[J].分析化学,2003,31(1):52-54. 被引量:24
  • 3HUANG Y M,ZHANG Z J.Binding study of drug with bovine serum album using a combined technique of microdialysis with flow-injection chemiluminescent detection[J].Journal of Pharmaceutical and Biomedical Analysis,2004,35:1293-1299.
  • 4WASCH K D,OKERMAN L,BRABANDER H D.Detection of residuses of tetracycline antibiotics in perk and chicken meat [ J ].Analyst,1998,123:2737-2741.
  • 5蔡秀成,潘维平,邢立新,王文,王驰,林丰全,李青.动物组织中土霉素、四环素、金霉素残留量分析[J].农业与技术,2000,20(4):41-42. 被引量:11
  • 6ZHANG W,DANIELSON N D.Characterization of a micro spiral flow cell for chemiluminescence detection [ J ].Microchemical Journal,2003,75:255-264.
  • 7SELLER K,HARRISON D J,MANZ A.Planar glass chips for capillary electrophoresis:repetitive sample injection,quantitation,and separation efficiency[J].Anal Chem,1993,65(10):1481-1488.
  • 8KIBA N,TOKIZAWA T,KATO S,et al.Flow-through micro sensor using immobilized peroxidase with chemiluminometric FIA system for determining hydrogen peroxide[ J].Analytical Sciences,2003,19:823-827.

二级参考文献6

  • 1[1]Diaz T, Guiberteau A, Salinas F. Anal. Lett., 1990, 23(4): 607~616
  • 2[2]Oka H, Ito Y, Matsumoto H. J. Chromatogr. A, 2000, 882: 109~133
  • 3[3]Oka H, Uno K, Harada K-I, Yasaka K, Suzuki M. J. Chromatogr., 1984, 298: 435~443
  • 4[4]Oka H, Matsumoto H, Uno K, Harada K-I, Kadowaki S, Suzuki M. J. Chromatogr., 1985, 325: 265~274
  • 5[5]Oka H, Ikai Y, Kawamura N, Uno K, Yamada M, Harada K-I, Uchiyama M, Asukabe H, Mori Y, Suzuki M. J. Chromatogr., 1987, 389: 417~426
  • 6[6]Sokol J, Matisova E. J. Chromatogr. A, 1994, 669: 75~80

共引文献33

同被引文献234

引证文献13

二级引证文献89

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部