期刊文献+

埋入式F-P光纤应变传感器在混凝土桥梁健康监测中的应用研究 被引量:5

Application research of submerged F-P optical fiber strain sensor used in the health monitoring of concrete bridge
原文传递
导出
摘要 对基于白光干涉的埋入式F_P光纤应变传感器的测试原理及主要结构参数进行了分析,介绍了该埋入式传感器的研制工艺特点。通过对传感器的性能考核试验,验证了该传感器具有优良的精度稳定性和耐久性,通过秦沈客运专线辽河特大桥施工过程监测试验,验证了该传感器满足桥梁施工现场复杂状况下混凝土结构应变监测的要求。由于该传感器的成本不及同类型进口产品的1/5,具有广阔的普及应用前景。 The test theory and the main structural parameter of submerged F-P optical fiber temperature sensor which was based on the theory of white light interference were researched, and the production technology was introduced. The performance test of the optical fiber strain sensor verifies that the optical fiber strain sensor has the merits of good accuracy lasting and durability, and the monitoring test in the construction stage of Liao-river super-bridge which located in Qin-Shen passenger private line verifies that the optical fiber strain sensor can meet the demands of strain monitoring in concrete structure under the complex conditions of construction field. Because the cost of this kind of sensor less than the quintile of the same kind of imported product, the submerged F-P optical fiber temperature sensor has extensive application foreground.
出处 《光学技术》 EI CAS CSCD 北大核心 2006年第3期349-352,共4页 Optical Technique
基金 铁道部科技攻关项目(2001G018)
关键词 白光干涉 光纤传感器 应变测量 white light interference F-P optical fiber sensor strain measurement
  • 相关文献

参考文献10

二级参考文献10

  • 1欧进萍.重大工程结构的累积损伤与安全评定.走上21世纪的中国力学.中国科协第9次“青年科学家论坛”[M].北京:清华大学出版社,1996..
  • 2黄尚廉.智能材料系统与结构工程构造安全监控的一条崭新思路.中国工程院第三次院士大会学术报告之七[M].北京,1996..
  • 3蔡德所.大坝裂缝光纤监测技术研究及坝基稳定性分析.哈尔滨建筑大学博士后研究报告[M].,1998..
  • 4Lee C E, Taylor H F. Sensors for smart structures based on the Fabry-Perot interferometer. Fiber Optic Smart Structures, 1995. 249-267
  • 5Feng Jun. The rersearch on fiber Fabry-Perot interferometer's accuracy and its application on the bridge monitoring. Chongqing University Ph. D. thesis, 2000.12(in Chinese)
  • 6Born M. Wolt E. Principles of Optics(光学原理).Beijing: Science Press, 1978. 422-429(in Chinese)
  • 7Vikram Bhatia, Kent et al.. Recent developments in optical-fiber-based extrinsic Fabry-Perot interferometric strain sensing technology. Smart .Mater. Struct, 1995.246-251
  • 8崔飞,袁万城,史家钧.传感器优化布设在桥梁健康监测中的应用[J].同济大学学报(自然科学版),1999,27(2):165-169. 被引量:87
  • 9董聪,丁辉,高嵩.结构损伤识别和定位的基本原理与方法[J].中国铁道科学,1999,20(3):89-94. 被引量:61
  • 10李戈,秦权,董聪.用遗传算法选择悬索桥监测系统中传感器的最优布点[J].工程力学,2000,17(1):25-34. 被引量:73