期刊文献+

Numerical Study on Plume Interaction Above An AlternatingDiffuser in Stagnant Water 被引量:1

Numerical Study on Plume Interaction Above An AlternatingDiffuser in Stagnant Water
下载PDF
导出
摘要 The plume interaction above an alternating diffuser in stagnant water is studied with 3D Reynolds-averaged NavierStokes equations (RANS) combined with a buoyancy-extended κ-ε model. The steady three-dimensional turbulent flow and temperature fields are computed by use of the finite volume method on a non-uniform high resolution orthogonal grid. The numerical predictions demonstrate a generic flow pattern for different turbulent heated jet discharges: the buoyant jets on each side of the diffuser first merge to form an essentially two-dimensional plume which bends back toward the diffuser centerline due to a low pressure cavity. In general, an under-pressure exists in the cavity until the plumes merge; the pressure increases to slightly positive afterwards. Two-dimensionality of the scalar and flow field is attained much later than the point of zero pressure. The position of merging point is governed by mainly four parameters - the discharge densimetfic Froude number, the port diameter and space, and the horizontal distance between alternating jet nozzles. A formula from numerical simulations is obtained through regression analysis and it is used to predict the position of plume merging point. The predicted temperature fields are comparable to previous experiments. The plume interaction above an alternating diffuser in stagnant water is studied with 3D Reynolds-averaged NavierStokes equations (RANS) combined with a buoyancy-extended κ-ε model. The steady three-dimensional turbulent flow and temperature fields are computed by use of the finite volume method on a non-uniform high resolution orthogonal grid. The numerical predictions demonstrate a generic flow pattern for different turbulent heated jet discharges: the buoyant jets on each side of the diffuser first merge to form an essentially two-dimensional plume which bends back toward the diffuser centerline due to a low pressure cavity. In general, an under-pressure exists in the cavity until the plumes merge; the pressure increases to slightly positive afterwards. Two-dimensionality of the scalar and flow field is attained much later than the point of zero pressure. The position of merging point is governed by mainly four parameters - the discharge densimetfic Froude number, the port diameter and space, and the horizontal distance between alternating jet nozzles. A formula from numerical simulations is obtained through regression analysis and it is used to predict the position of plume merging point. The predicted temperature fields are comparable to previous experiments.
出处 《China Ocean Engineering》 SCIE EI 2006年第2期289-302,共14页 中国海洋工程(英文版)
基金 ThisworkwassupportedbyagrantfromtheHongKongResearchGrantsCouncil(HKU-7518/03E) agrantfromTongjiUniversity(No.0200144005)
关键词 alternating diffuser merging point plume interaction low pressure cavity ednsimetric Froude number turbulence modelling computational fluid dynamics κ-ε model enviromental hydraulics alternating diffuser merging point plume interaction low pressure cavity ednsimetric Froude number turbulence modelling computational fluid dynamics κ-ε model enviromental hydraulics
  • 相关文献

参考文献29

  • 1[1]Baumgartner,D.J.,Frick,W.E.and Roberts,P.J.W.,1993.Dilution models for effluent discharges (second edition),EPA/600-r-93/139,U.S.Environmental Protection Agency,ERL-Narragansett,Newport,Oregon.
  • 2[2]Cederwall,K.,1968.Hydraulics of marine waste disposal,Tech.Rep.No.42,Hydraulic Div.,Chalmers Institute of Technology,Goteborg,Sweden.
  • 3[3]Chu,V.H.and Lee,J.H.W.,1996.General integral formulation of turbulent buoyant jets in cross-flow,J.Hydraul.Eng.,ASCE,122(1):27~34.
  • 4[4]Davidson,M.J.and Pun,K.L,1998.Hybrid model for the prediction of initial dilutions from outfall discharges,J.Hydraul.Eng.,ASCE,124(12):1188~1197.
  • 5[5]Davidson,M.J.,Wang,Y.,and Pun,K.L.,1995.A length-scale model for the merging of jets in a coflow,Proc.10th ASCE Eng.Mech.Conf.,ASCE,New York,215~218.
  • 6[6]Davidson,M.J.,1989.The behaviour of single and multiple horizontally discharged buoyant flows in a non-turbulent coflowing ambient fluid,PhD thesis,University of Canterbury,New Zealand.
  • 7[7]Doneker,R.L.and Jirka,G.H.,1990.Expert system for hydrodynamic mixing zone analysis of conventional and toxic submerged single port discharges (CORMIX1),EPA/600/3-90/012,1990,USEPA.
  • 8[8]Hirst,E.A.,1971.Buoyant jets discharged to quiescent stratified ambient,J.of Geophys.Res.,76(30):7375~7384.
  • 9[9]Holley,E.R.and Jirka,G.H.,1986.Mixing and solute transport in rivers,Tech.Rep.E-86-11,US Army Engineers Waterways Experiment Station,Vicksburg,Mississippi.
  • 10[10]Hutchinson,B.R.and Raithby,G.B.,1986.A multigrid method based on the additive correction strategy,Numer.Heat Transfer,9,511~537.

同被引文献3