摘要
对洁净室常用的几种典型空调系统如何合理选择,以避免或减少冷、热抵消以及实现最小新风量优先的策略等进行分析、讨论。并举例对有关问题进行引证。
How to select the reasonable system from several types of typical system to avoid or reduce the offset of cool and heat in the air handling process and to accomplish the strategy of minimum make-up air volume priority are analyzed and discussed. And an example of calculation is give to illustrate the related issues.
出处
《洁净与空调技术》
2006年第2期1-3,11,共4页
Contamination Control & Air-Conditioning Technology
关键词
空调系统
最小新风量优先
洁净(所需)风量
空调(所需)风量
除湿(所需)风量
Air-conditioning system Minimum make-up air volume priority Air volume required for cleanliness Air volume required for air-conditioning Air volume required for moisture removal