期刊文献+

镁及镁合金中微量磷的测定方法研究 被引量:8

Study on determination method of micro-amounts of phosphorous in magnesium and its alloy
下载PDF
导出
摘要 磷与钼酸铵形成磷钼杂多酸络幌物,用乙酸丁酯萃取分离,用SnCl2还原反萃取后借磷钼蓝光度法测定镁及镁合金中微量磷.在波长700nm处工作曲线线性范围0~1.5μg/mL,相关系数为0.9995,络合物表观摩尔吸光系数ε=1.45×10^4L·mol^-1·cm^-1,相对标准偏差在1.40%~3.10%之间,加标回收率在99.3%~101.0%之间,本法与ICP法相对照结果比较满意. Micro-amounts of phosphorous and its alloy was reduced to divalent with tin( Ⅱ ) chloride and then reacted with ammonium molybdate to form a phosphorous-molybdate complex. It was extracted with butyl ethanoate and total phosphorous in the sample was determined by phosphorous-molybdate blue spectrophotometry. Linear range is 0 - 1.5 μg/mL ( r = 0.9995) for phosphorous at the wavelength of 700 nm, the apparent molar absorptivity of complex (e) is 1.45 ×10^4 L·mol^-1·cm^-1. The recovery of the method is in the range of 99.3% - 101.0% and RSD is 1.4% -3.1%. In comparison with the results obtained by ICP, the results were satisfactory.
作者 石磊
出处 《分析试验室》 CAS CSCD 北大核心 2006年第6期67-69,共3页 Chinese Journal of Analysis Laboratory
关键词 镁及镁合金 乙酸丁酯 萃取光度法 Magnesium and its alloy Phosphorous Butyl ethanoate Extractive spectrophotometry
  • 相关文献

参考文献3

  • 1宋恩烈,张铨铭.实用无机光度分析.沈阳:辽宁科学技术出版社,1983,108
  • 2于敏.全国第七届轻金属分析学术会议论文集.山西铝厂,1998,151
  • 3吴继祖.磷砷的萃取光度法测定[J].理化检验:化学分册,1976,(6):39-39.