新型三相逆变器及其调制技术的研究 被引量:2

Research on Novel Three-phase Inverter and its Modulation Technique
下载PDF
导出
摘要 提出了一种新型三相不带或带有很小直流连接电容的逆变器,介绍了仅通过改变相应的调制波来消除逆变器输出电压谐波的重构SPWM技术。该逆变器采用了调制波重构技术,很大程度上消除了输出电压的谐波,同时减小了直流输出滤波器的尺寸。最后通过仿真和实验比较了基于调制波重构技术的新型变换器和基于传统技术的变换器的性能,结果验证了理论分析的正确性。 A novel three-phase uncontrollable rectifier inverter without or with a quite small dc-link capacitor, accordingly,a novel reconstruction technology,Modulation Wave Reconstruction Sine Pulse Width Modulation (MWR- SPWM) which can greatly eliminate harmonics in inverter's output voltage are proposed.Because the MWR-SPWM technique is adopted, the sizes of the input AC filter and the output AC filter are reduced.The performance of this inverter using MWR-SPWM technique is compared with traditional inverter by simulation and experiment,and the results show the theoretical analysis is correct.
机构地区 哈尔滨工业大学
出处 《电力电子技术》 CSCD 北大核心 2006年第3期6-7,共2页 Power Electronics
关键词 逆变器/调制波重构-正弦脉宽调制 谐波抑制 inverter / MWR-SPWM harmonics elimination
  • 相关文献

参考文献5

  • 1D Shen, P W Lehn. Fixed-frequency Space Vector Modulation Control for Three-phase Four-leg Active Power Filters[J].IEE Proc. Electr. Power Appl., 2002,149, (4):268-274.
  • 2Wang Hao, Zhang Chao, Yang Geng, et al. Detective and Close-loop Control Methods for Selective-Harmonic-Compensation Active Power Filter [A].The 4th International Power Electronics and Motion Control Conference[C].2004:206-209.
  • 3L M Malesani, L Rossetto,P Tenti,et al.AC/DC/AC PWM Converter with Reduced Energy Storage in the DC Link[J].IEEE Trans. on Ind. Applicat., 1995,31: 287-292.
  • 4N Hur,Jinhwan Jung,Kwanghee Nam.A Fast Dynamic DC-link Power-balancing Scheme for a PWM Converter-inverter System[J].IEEE Trans. on Ind. Applicat., 2001,48:794-803.
  • 5王建元,纪延超,赵般多.一种新的单相逆变电源及其调制方式的研究[J].中国电机工程学报,2003,23(7):62-66. 被引量:18

二级参考文献5

共引文献17

同被引文献21

  • 1彭海应,陈柏超,彭浒.一种新型谐波抑制及无功补偿装置[J].电力电子技术,2004,38(6):34-36. 被引量:8
  • 2解绍锋,李群湛,赵丽平.谐波国家标准有关问题的探讨[J].电网技术,2006,30(13):94-97. 被引量:21
  • 3周胜灵,何离庆.基于新型开关策略的死区补偿技术[J].重庆大学学报(自然科学版),2006,29(8):91-94. 被引量:3
  • 4Erika Twining, Donald Grahame Holmes. Grid current regulation of a three phase voltage source inverter with an LCL input filter[J]. IEEE Transactions on Power Electronics, 2003, 18 (3) : 888-895.
  • 5Qiao C, Smedley K. Three phase grid-connected inverters interface for alternative energy sources with unified constant-frequency integration control[C]//Proc of IAS' 2001 Conf. California, USA: [s.n.], 2001:2675 -2682.
  • 6Qiao Chongming, Smedley Keyue M. A general three-phase PFC controller for rectifiers with a parallel-connected dual boost topology[J]. IEEE Transactions on Power Electronics, 2002, 17(6): 995 -934.
  • 7Figueres E, Garcer G, Sandia J, et al. Sensitivity study of the dynamics of there phase photovoltaic inverters with an LCL grid filter [J]. IEEE Transactions on Industrial Electronics, 2009, 56(3): 706-717.
  • 8Shen G, Xu D, Cao L, et al. An improved control strategy for grid-connected voltage source inverters with an LCL filter[J]. IEEE Transactions on Power Electronics, 2008, 23(4) :1899- 1906.
  • 9Timbus A V, Teodoreseu R, Blaabjerg F, et al. Linear and nonlinear control of distributed power generation systems[C]// Proc of IAS'2006. Aalborg, Denmark: [s. n. ], 2006: 1015- 1023.
  • 10Bueno E J, Espinosa F, Rodriguez F J, et al. Current control of voltage source converters connected to the grid through an LCL-filter[C]//Proc of PESC'2004. Madrid, Spain: [s. n. ], 2004, 68-73.

引证文献2

二级引证文献15

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部