酶联免疫破伤风抗体定量试剂的研制及应用 被引量:2

Study and application of quantitative ELISA kit in detection of antibody to tetanus
下载PDF
导出
摘要 制备一种精确的破伤风抗体定量试剂,用于人源破伤风抗体的定量及人群破伤风抗体水平的测定.以人源破伤风免疫球蛋白国家标准品建立定量反应曲线,经系统优化后建立双抗原夹心法定量检测系统.定量反应曲线显示,抗体浓度在10~120mIU/ml之间,相关系数r = 0.9993.精密度(CV)≤7 %.实际应用验证,未经(TTC)免疫的献血员中,具有保护性抗体水平(0.01IU/ml)的比例只占12.2%.经3针(TTC)免疫后,抗体水平均大于0.01IU/ml,经动物体内中和试验法(NT)定量的3批破伤风免疫球蛋白,用制备的酶联免疫破伤风抗体定量试剂测定,其回收率分别为109%、98%和93%.结论,该试剂可用于破伤风抗体的精确定量. To develop an accurate quantitative EHSA kit that can be used for the quantifying human antibody to tetanus and estimating antibody responses in tetanus toxoid immunized groups, Linear regression curves were developed by using the national standard preparation (tetanus immunoglobulin from human). A sandwich ELISA kit was developed by optimizing all kinds of conditions and applicability was validated. The optimal linear range of regression curve was in a range of 10mIU/ ml-120mIU/ml ( r =0. 9993 ). Precision was equal to or less than 7%. The samples from immunized group were detected by EIA, the result indicated that the ratio for possessing protective antibody only accounted for 12.2% in all tested samples, and after immunized three times, the antibodies all reachod to a protective level above 0.01IU/ml. Three lots of human tetanus immunoglobulins were quantified by neutralization test ( NT), the repeatabilities were 109%, 98%, 93%, respectively performed by using the ELISA kit.
出处 《微生物学免疫学进展》 2006年第2期23-27,共5页 Progress In Microbiology and Immunology
关键词 酶联免疫检测 破伤风抗体 诊断试剂 ELISA Tetanus antibody Diagnostic reagent
  • 相关文献

参考文献3

  • 1迮文远 苏万年.我国正常人群破伤风免疫监测[J].中华流行病学杂志,1987,8:133-135.
  • 2WHO/GPV/95.1.Global Programme for Vaccine and Immunization,Programme Report[R].1994.
  • 3赵建荣,顾磊,马霄,等.人源破伤风免疫球蛋白国家标准品的研制.第七次全国生物制品学术会议论文汇编[G].2001-2003,217.

共引文献3

同被引文献22

引证文献2

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部