期刊文献+

SXO光度法测定铜合金中微量铅的研究 被引量:2

Study on Determining Micro - Lead Contaninde in Copper Alloy by SXO Photometric Analysis
下载PDF
导出
摘要 本文确定了以硫酸锶、硫酸铅快速沉淀分离杂质,在pH=55时,铅与半二甲酚橙(SXO)形成红色配合物并于λ=540nm处进行光度法测定微量铅的分析条件所拟方法精确度高、稳定性好、简便快速,适合于铅含量在0.003%~0.22%的铜合金的生产检验. This article defined the analysing conditions of precipitating foreign substances rapidly by lead sulphate and strontium sulphate, and of that when pH = 5. 5, Lead and SXO form red coordination,and determined at λ = 540nm. This Method has a better accuracy and a better stableness. It is covement and save time, and it is fit for the production of copper alloy when lead content is at about 0. 003 %  ̄0. 22%.
作者 时文中
出处 《河南大学学报(自然科学版)》 CAS 1996年第1期25-29,共5页 Journal of Henan University:Natural Science
关键词 半二甲酚橙 光度法 铜合金 测定 semixylenol orange photometric Analysis copper alloy microlead
  • 相关文献

参考文献2

二级参考文献1

  • 1M. Oosting. Eine neue selektive und empfindliche Wismutbestimmung[J] 1956,Mikrochimica Acta(1-3):528~534