摘要
通过现场检测及试验分析,找出了两台16MnR钢制换热器在实际使用中焊缝开裂的原因,并提出了解决开裂问题的理论依据及所采取的切实可行的措施.
The reason for weld cracking of two heat exchangers made from 16MnR steel is fund out by on site inspection and experimental analysis. The practical measures to solve cracking arc put forward based on theoretical principle.