期刊文献+

存储区域网络中路径容错及负载均衡的研究 被引量:1

Research on Fault Tolerant Paths and Load Balancing for Storage Area Networks
下载PDF
导出
摘要 为利用存储区域网络的冗余路径,在主机上加入驱动程序对逻辑单元(LUN)的输入/输出请求进行截获。在故障路径上的I/O请求失败后,由驱动程序在正常路径上重新执行。路径失败时I/O请求直接发送给HBA驱动程序,避免了磁盘驱动程序中的无效重试过程,缩短了故障切换时间。I/O请求被分配到多条路径上,提高了主机的吞吐能力,缩短了I/O平均响应时间。 To utilize the redundant paths in storage area networks, a storage path driver (SPD) is proposed and implemented to hook I/O requests bound for the logical units. The SPD driver routes all failed I/O requests on the failed path through survival paths. The failover time is reduced by skipping the retry operations of the disk device driver. I/O requests of the logical units are distributed among all physical paths, the host load is balanced on these parallel paths to improve the I/O performance, including increasing the I/O throughput and shortening the average I/O response time.
出处 《计算机工程》 EI CAS CSCD 北大核心 2006年第12期32-33,41,共3页 Computer Engineering
基金 国家自然科学基金资助项目(60273073)
关键词 存储区域网络 容错 高可用性 负载均衡 Storage area network Fault tolerance High availability Load balancing
  • 相关文献

参考文献5

  • 1付长冬,舒继武,吴昊,沈美明.SAN存储系统的I/O路径控制与管理[J].小型微型计算机系统,2004,25(5):811-814. 被引量:1
  • 2Sun Weitao,Shu Jiwu,Zheng Weimin.Storage Virtualization System with Load Balancing for SAN[C].International Workshop on Storage Grid and Technologies,2004,254-261.
  • 3Wu Song,Jin Hai,Tan Guang.Symmetrical Declustering:A Load Balancing and Fault Tolerant Strategy for Clustered Video Servers[C].International Conference on Computational Science and Its Applications,2003:199-208.
  • 4Anderson M,Mansfield P.SCSI Mid-level Multipath[C].Proceedings of the Linux Symposium,Ottawa,2003.
  • 5谭毓安,曹元大.Design and Implementation of an RDP Device Driver for Windows 2000[J].Journal of Beijing Institute of Technology,2003,12(3):260-264. 被引量:2

二级参考文献14

  • 1[1]Ashish Paleker. Design and implementation of a linux scsi target for SAN [ C]. Proceedings of 5th Annual Linux Showcase &Conference. USENIX, 2001.
  • 2[2]Jae-Chang Namggong etc. Design and Implementation of a Fibre Channel Network Driver for SAN-attached RAID controllers[J].IEEE/ACM Transactions on Networking, 2001.
  • 3[3]Ashish A. Palekar etc. Design and Implementation of a SCSI Targt For Storage Area Networks [D]. University of New Hampshire, 2001.
  • 4[4]Garth A. Gibson. Network-attached storage architecture [J].Communication of the ACM, 2000,43:11 ~ 17.
  • 5[5]ANSI INCITS xxx-199x, SCSI Fibre channel protocol - 2 (FCP2)[Z]. Project /T10 1144D/Rev 07a,2002.
  • 6[6]ANSI INCITS xxx-199x,Fibre Channel HBA API (FC-HBA)[Z]. Project T11/1568-D Rev 03,2002.
  • 7[7]Ruemmler C and Wilkes J. An introduction to disk drive modeling[J]. IEEE Computer, 1994,27(3) :17~28.
  • 8[8]IBM Corporation. IBM Storage Tank:A distributed storage system[Z]. 2002.
  • 9Lü Jie,Mo Yiqun,Luo Weixiong.High-speed real-time data acquisition system realized by interleaving/multiplexing technique[].Journal of Beijing Institute of Technology.2000
  • 10He Xubin,Yang Qing.A DCD filter driver for Windows NT 4[]..1999

共引文献1

同被引文献4

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部