期刊文献+

PC机辅助MR脑灌注成像初步研究 被引量:1

MR Cerebral Perfusion Imaging on Personal Computer
下载PDF
导出
摘要 目的:研究PC机辅助MR脑灌注成像软件,探讨其临床应用价值。方法:在PC机上使用MR脑灌注成像软件,对5例健康人和18例脑缺血患者的灌注图像进行后处理,计算出有关脑灌注参数图,包括相对脑血流量(rrCBF)图、相对脑血容量(rrCBV)图、局部灌注达峰时间(TTP)图和团注平均通过时间(bMTT)图。结果:应用MR脑灌注成像软件可以在PC机上实现灌注图像的后处理,脑灌注参数图能够为脑缺血患者提供有价值的脑血液动力学信息,显示灌注异常的范围。结论:PC机辅助MR脑灌注成像软件简单易行,可显示常规MR无法显示的血流动力学异常,对临床和科研具有重要价值。 Objective:To introduce a method of making MR cerebral perfusion weighted imaging based on Personal Computer (PC) and probe into the clinical diagnostic value of the method. Methods: MR cerebral perfusion weighted imaging was performed in 5 normal adults and 18 patients with cerebral ischemia. Perfusion-weighted images were analyzed with a software running on PC. Cerebral perfusion mapping with parameters including relative regional cerebral blood flow (rrCBF), relative regional cerebral blood volume (rrCBV),time to peak (TTP) and bolus mean transit time (bMTT) were conducted on PC. Results:The process and analysis could be performed successfully on PC. The cerebral perfusion mapping provided valuable hemodynamic information and showed the extent of perfusion disturbances. Conclusion:PC aided mapping of MR cerebral perfusion weighted imaging is a simple and accessible technique for delineating the hemodynamic abnormalities. The methods could obtain more diagnostic information,and has great practical value in both clinical and research workes.
出处 《放射学实践》 2006年第6期546-548,共3页 Radiologic Practice
关键词 灌注 磁共振成像 计算机辅助 Perfusion,brain Magnetic resonance imaging Computer-assisted
  • 相关文献

参考文献6

  • 1Neumann-Haefelin T,Wittsack HJ,Wenserski F,et al.Diffusion-and Perfusion-weighted MRI:the DWI/PWI Mismatch Region in Acute Stroke[J].Stroke,1999,30(8):1591-1597.
  • 2Perkins CJ,Kahya E,Roque CT,et al.Fluid-attenuated Inversion Recovery and Diffusion-and Perfusion-weighted MRI Abnormalities in 117 Consecutive Patients with Stroke Symptoms[J].Stroke,2001,32(12):2774-281.
  • 3卢洁,李坤成,等.MR脑灌注与弥散加权成像[J].中国医学影像技术,2002,18(10):1083-1085. 被引量:21
  • 4Ostergaard L,Weisskoff RM,Chesler DA,et al.High Resolution Measurement of Cerebral Blood Flow Using Intravascular Tracer Bolus Passages.Part1:Mathematical Approach and Statistical Analysis[J].MRM,1996,36(5):715-725.
  • 5Ostergaard L,Weisskoff RM,Chesler DA,et al.High Resolution Measurement of Cerebral Blood Flow Using Intravascular Tracer Bolus Passages.Part2:Experimental Comparison and Preliminary Results[J].MRM,1996,36(5):726-736.
  • 6卢洁,李坤成.CT脑灌注成像研究[J].国外医学(临床放射学分册),2002,25(3):149-151. 被引量:7

二级参考文献39

  • 1[1]Perkins CJ,Kahya E,Roque CT,et al.Fluid-attenuated inversion recovery and diffusion- and perfusion-weighted MRI abnormalities in 117 consecutive patients with stroke symptoms[J].Stroke,2001,32(12):2774-2781.
  • 2[2]Barber PA,Consolo HK,Yang Q,et al.Comparison of MRI perfusion imaging and single photon emission computed tomography in chronic stroke[J].Cerebrovasc Dis,2001,11(2):128-136.
  • 3[3]Edelman RR,Wielopolski P,Schmitt F.Echo-planar imaging[J].Radiology,1994,192(3):600-612.
  • 4[4]Wu O,Koroshetz WJ,Ostergaard L,et al.Predicting tissue outcome in acute human cerebral ischemia using combined diffusion- and perfusion-weighted MR imaging[J].Stroke,2001,32(4):933-942.
  • 5[5]Astrup J,SiesJ BK,Symon L.Thresholds in cerebral ischemia--the ischemic penumbra[J].Stroke,1981,12(6):723-725.
  • 6[6]Schlaug G,Siewert B,Benfield A,et al.Time course of the apparent diffusion coefficient(ADC) in human stroke[J].Stroke,1997,28(1):252.
  • 7[7]Barest GD,Sorensen AG,Gonzalez RG,Magnetic resonance imaging of cerebral infarction[J].Topics Magn Reson Imaging,1998,9(1):199-207.
  • 8[8]Sorensen AG,Buonanno FS,Gonzalez RG,et al.Hyperacute stroke:evaluation with combined multisection diffusion-weighted and hemodynamically weighted echo-planar MR imaging[J].Radiology,1996,199(2):391-401.
  • 9[9]Lansberg MG,Tong DC,Norbash AM,et al.Intra-arterial rtPA treatment of stroke assessed by diffusion- and perfusion-weighted MRI[J].Stroke,1999,30(3):678-680.
  • 10[10]Nighoghossian N,Hermier M,Berthezene Y,et al.Early diagnosis of hemorrhagic transformation:diffusion/perfusion-weighted MRI versus CT scan[J].Cerebrovasc Dis,2001,11(3):151-156.

共引文献26

同被引文献3

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部