期刊文献+

闭合复位经皮克氏针内固定治疗C型桡骨远端骨折 被引量:1

Closed reduction and percutaneous pinning for the treatment of type C distal radial fracture
下载PDF
导出
摘要 目的探讨闭合复位经皮克氏针内固定治疗C型桡骨远端骨折疗效。方法应用闭合性复位经皮克氏针内固定C型桡骨远端骨折33例。结果全部病例均随访1·5年以上,按改良Shea评定法进行疗效评定,优良率为81·82%。结论该术式创伤较小,操作简单安全,固定可靠,术后患者功能恢复满意。 Objective To investigate the effect of closed reduction and perautaneons pinning for the treatment of type C distal radial fracture.Methods 33 cases with type C distal radial fractores were treated with closed reduction and percutaneous pinning. Results All cases were followed up for over 1.5 years. Aceording to the criteria of Shea. the excellent and good rate was 81.28%. Conelusions This proeedure has advantages of minimal trauma. simple, safe and rigid fisation, which can provide satisfactory functional reeovery.
作者 陈舰 郁凯乐
出处 《临床骨科杂志》 2006年第3期243-244,共2页 Journal of Clinical Orthopaedics
关键词 桡骨骨折 骨折固定术 radius fraclures fracture fisation, internal
  • 相关文献

参考文献6

  • 1白建忠,俞思勤,陈舰,郁凯乐.B、C型桡骨远端骨折的治疗[J].临床骨科杂志,2003,6(2):141-143. 被引量:43
  • 2Kamano M,Honda Y,Kazuki K,et al.Palmar plating for dorsally displaced fractures of the distal radius[J].Clin Orthop Relat Res,2002,(397):403-408.
  • 3Sun J S,Chang C H,Wu C C et al.Extra-articular deformity in distal radial fractures treated by external fixation[J].Can J Surg,2001,44(4):289-294.
  • 4Broos P Y L,Fourneau I A,Stoffelen D V.Fractures of the distal radius.current concepts for treatment[J].Acta Orthop Belg,2001,67(3):211-218.
  • 5Christensen O M,Christiansen T C,Krasheninnikoff M,et al.Plaster cast compared with bridging external fixation for distal radiusfractures of the Colles′ type[J].Int Orthop,2001,24(6):358-360.
  • 6Kaempffe F A,Walker K M.External fixation for distal radius fractures:Effect of distraction on outcome[J].Clin Orthop Relat Res,2000,(380):220-225

二级参考文献12

  • 1Swigart CR, Wolfe SW. Limited incision open techniques for distal radius fracture management[ J]. Orthop Clin North Am, 2001 ;32(2) :317 -327.
  • 2Fitoussi F, Ip WY, Chow SP. Treatment of displaced intra-aticular fractures of the distal end of the radius with plates[ J], J Bone Joint Surg Am, 1997 ;79 ( 9 ) : 1303-1312.
  • 3Kamano M, Honda Y, Kazuki K et al. Palmar plating for dorsally displaced fractures of the distal radius [ J ]. Clin Orthop, 2002;(397) :403- 408.
  • 4Sun JS, Chang CH, Wu CC et al. Extra-articular deformity in distal radial fractures treated by external fixation [ J ]. Can J Surg, 2001 ;44(4) :289 -294.
  • 5Broos PL, Fourneau IA, Stoffelen DV. Fractures of the distal radius, current concepts for treatment[ J]. Acta Orthop Belg, 2001 ;67(3) :211 -218.
  • 6Christensen OM, Christiansen TC, Krasheninnikoff Met al. Plaster cast compared with bridging external fixation for distal radiusfractures of the Colles' type[J]. Int Orthop, 2001 ;24(6) :358 -360.
  • 7Kaempffe FA, Walker KM. External fixation for distal radius fractures: effect of distraction on outcome [J]. Clin Orthop, 2000;(380) :220-225.
  • 8Kapoor H, Agarwal A, Dhaon BK. Displaced intra - articular fractures of distal radius: a comparative evaluationof results following closed reduction, external fixation and open reduction with internal fixation[J]. Injury, 2000;31 (2) :75-79.
  • 9Dee W, Klein W, Rieger H. Reduction techniques in distal radius fractures[J]. Injury, 2000;31 ( Suppl 1 ) :48-55.
  • 10Bradway JK, Amadio PC, Cooney WP. Open reduction and internal fixation of displaced, comminuted intra-articular fractures of the distal end of the radius[J]. J Bone Joint Surg Am, 1989; 71 (6) :839- 847.

共引文献42

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部