摘要 通过自行设计加工的试验装置,进行生物接触氧化技术在景观水体功能恢复中的试验研究。待处理的景观水体ρ(CODCr)为25~35mg/L,ρ(NH3-N)为2.2~3mg/L。ρ(TP)为0.55~0.85mg/L,有机负荷低,且水质变化幅度大。试验结果表明。在合适的运行参数下,生物接触氧化技术可以使经过处理的景观水体的ρ(CODCr)、ρ(NH3-N)、ρ(TP)分别降至14.62mg/L、0.26mg/L、0.19mg/L。满足地表水Ⅲ类水质标准,达到景观水体水质要求。 The experimental research about application of catalytic oxidation in sight water resumption has been carried out through our own test device. The slight water to be disposed has low organic capacity with large range of water quality and the concentration of CODCr is in the range of 25-35 mg/L and 2.2- 3 mg/L for NH3 - N and 0.55- 0.85 mg/L for TP respectively. The experimental results show that at the suitable operating conditions biological catalytic oxidation could lower the concentration of CODer, NH3-N and TP to be 14. 62 mg/L,0. 26 mg/L,0. 19 mg/L respectively to high extent, which is lower than the standard of Ⅲ class water quality and can meet the need of sight water.
出处 《吉林大学学报(地球科学版)》 EI CAS CSCD 北大核心 2006年第3期458-461,共4页 Journal of Jilin University:Earth Science Edition
基金 国家自然科学基金项目(40372113)
关键词 生物接触氧化技术 景观水体 最佳曝气量 最佳水力停留时间 最佳气水比 biological catalytic oxidation sight water optimal aeration quantity optimal water power standing time optimal gas-water ratio