期刊文献+

改良硫代巴比妥酸荧光法测定血清过氧化脂质 被引量:58

Improvement of the Thiobarbituric Acid Fluorescence Analysis of Serum Lipoperoxides
下载PDF
导出
摘要 对目前使用的过氧化脂质(LPO)硫代巴比妥酸(TBA)荧光测定法进行了改进.血清样本在冰醋酸存在的条件下,100℃水解60min,LPO释放的雨二醛(MDA)与TBA形成复合物,用甲醇沉淀血清蛋白质并减少非特异性干扰,以λ=515nm、λem=550nm测定MDA-TBA复合物的荧光强度.此法操作简便、快速,结果准确,荧光稳定.LPO含量(以MDA表示)在0~20μmol/L与荧光强度呈线性关系(r=0.9994),最低检测限为0.16μmol/L,回收率为105.08%,重复性CV=4.23%. The thinbarbituric acid(TBA)fluorescence spectrophotometry of lipoperoxides(LPO),at present used for research,has been improved. This assay of serum LPO involves a hydrolysis in a diluted glacial acetic acid solution at 100℃ for 60 min and the hydrolysis product malondialdehyde (MDA) forms complex with TBAthe methanol precipitation of serumproteins reduces nonspecific interference.The fluorecence intensity of the MDATBA complex is measured at excitation wavelength 515nmThe method is simple,rapid accurate and steady The fuorescence intersity is positively correlatvie to the LPO concentration in the range of 0~20μmol/L The minimum detection limkt is 0.16μmol/L The average recovery rate is 105.8 % Precision (CV)is 4023%
出处 《生物化学与生物物理进展》 SCIE CAS CSCD 北大核心 1996年第2期175-179,共5页 Progress In Biochemistry and Biophysics
关键词 血清诊断 过氧化脂质 荧光 分光光度法 lipoperoxides,fluorescence,sectrophotometry
  • 相关文献

参考文献6

  • 1王振华,许绍辉.血清脂质过氧化物测定比色法与荧光法比较[J].上海医学检验杂志,1991,6(4):201-203. 被引量:11
  • 2向荣,生物化学与生物物理进展,1990年,17卷,3期,241页
  • 3陈国珍,荧光分析法(第2版),1990年
  • 4余嘉丽,中华医学检验杂志,1987年,10卷,1期,24页
  • 5钟顺福,临床检验杂志,1986年,4卷,3期,129页
  • 6魏明竟,国外医学临床生物化学与检验学分册,1984年,5卷,1期,6页