期刊文献+

全自动生化分析仪测定血清乳酸脱氢酶同工酶I 被引量:1

Studies on the Measurement of Lactate Dehydrogenase Isoenzyme I Activities by Using Automatic Analyzer
下载PDF
导出
摘要 应用α-糜蛋白酶和盐酸胍作为抑制剂选择性测定待测样品中乳酸脱氢酶同工酶I(LD-1).采用蛋白水解酶和抑制剂来破坏乳酸脱氢酶同工酶2~5(LD2~5)的活性,因此不需预处理待测样品,可直接用于自动生化分析仪.使用日立7150分析仪建立了LD-1分析仪建立了LD-1测定参数,方法变异系数(CV)2.7%~4.4%;测得结果(y)与LD-1电泳方法(x)相关良好,y=0.967x-1.957,r=0.992(n=37);检测了197名健康男女血清样品,确定LD-1参考值范围为29.78~59.26U/L,±s=(44.58±7.39)U/L. A very simple method to determine the activity of LD isoenzyme I by using αchymotrypsin and guanidine has been developed.LD-3~LD-5 can be completely inactivated and LD-2 can be partially inactivated byαchymotrypsin.Guanidine can further completely inactivate LD-2. This method has been used in automatic analyzer. The coefficient of variation of the proteolytic method is among 2.7% ~4.4%.Results obtained by the present method correlates with those by the electrophoresis method (r=0.992, y=0.967,x=1.957).In the present assay system,the reference value for LD-1 activity in healthy people ranges from 29.78~59.26 U/L.The study showed that the selective measurement of LD-1 isoenzyme method is rapid and accurate.It has great clinical significance.
出处 《生物化学与生物物理进展》 SCIE CAS CSCD 北大核心 1996年第2期187-190,共4页 Progress In Biochemistry and Biophysics
关键词 乳酸脱氢酶 同功酶I 自动生化分析仪 血清诊断 lactate dehydrogenase isoenzyme I guanidine inhibitor alpha-chymotrypsin automatic analyzer