摘要
分析了燃气机热泵热电冷三联供系统节能的热力学原理及应用优势,探讨了不同季节采用不同的联供运行模式一次能源利用率PER的情况,并就影响PER的主要因素——废热回收率、热泵性能系数及用于发电的燃气能量占燃气总能量的比例的变动效应进行了模拟计算,给出了燃气机热泵不同联供运行工况下PER的对比及规律。
Analyses the thermodynamics principle of high energy efficiency and applying advantages of the gas engine-driven heat pump(GEHP) combined cooling heating and power, and discusses the PER of the GEHP at different combined supply energy modes. Simulates the effects on the PER when heat recovery rate, heat pump performance coefficient and the ratio of generating electricity energy to total energy are changed in different seasons, and compares the PER under the different combined supply energy conditions.
出处
《暖通空调》
北大核心
2006年第6期44-46,9,共4页
Heating Ventilating & Air Conditioning
基金
北京市供热
供燃气
通风及空调工程重点实验室资助项目(编号:kF200401)
北京市人才强教资助项目
关键词
燃气机热泵
热电冷三联供
一次能源利用率
废热回收率
热泵性能系数
gas engine-driven heat pump,combined cooling heating and power, PER, heat recovery rate,performance coefficient of heat pump