期刊文献+

Impact of automatic threshold capture on pulse generator longevity 被引量:4

Impact of automatic threshold capture on pulse generator longevity
原文传递
导出
摘要 Background The automatic, threshold tracking, pacing algorithm developed by St.Jude Medical, verifies ventricular capture beat by beat by recognizing the evoked response following each pacemaker stimulus. This function was assumed to be not only energy saving but safe. This study estimated the extension in longevity obtained by AutoCapture (AC) compared with pacemakers programmed to manually optimized, nominal output. Methods Thirty-four patients who received the St. Jude Affinity series pacemaker were included in the study. The following measurements were taken: stimulation and sensing threshold, impedance of leads, evoked response and polarization signals by 3501 programmer during followup, battery current and battery impedance under different conditions. For longevity comparison, ventricular output was programmed under three different conditions: (1) AC on; (2) AC off with nominal output, and (3) AC off with pacing output set at twice the pacing threshold with a minimum of 2.0 V. Patients were divided into two groups: chronic threshold is higher or lower than 1 V. The efficacy of AC was evaluated. Results Current drain in the AC on group, AC off with optimized programming or nominal output was (14.33±2.84) mA, (16.74±2.75) mA and (18.4±2.44) mA, respectively (AC on or AC off with optimized programming vs. nominal output, P〈0.01). Estimated longevity was significantly extended by AC on when compared with nominal setting [(103±27) months, (80±24) months, P〈0.01). Furthermore, compared with the optimized programming, AC extends the longevity when the pacing threshold is higher than 1 V. Conclusion AC could significantly prolong pacemaker longevity; especially in the patient with high pacing threshold. Background The automatic, threshold tracking, pacing algorithm developed by St.Jude Medical, verifies ventricular capture beat by beat by recognizing the evoked response following each pacemaker stimulus. This function was assumed to be not only energy saving but safe. This study estimated the extension in longevity obtained by AutoCapture (AC) compared with pacemakers programmed to manually optimized, nominal output. Methods Thirty-four patients who received the St. Jude Affinity series pacemaker were included in the study. The following measurements were taken: stimulation and sensing threshold, impedance of leads, evoked response and polarization signals by 3501 programmer during followup, battery current and battery impedance under different conditions. For longevity comparison, ventricular output was programmed under three different conditions: (1) AC on; (2) AC off with nominal output, and (3) AC off with pacing output set at twice the pacing threshold with a minimum of 2.0 V. Patients were divided into two groups: chronic threshold is higher or lower than 1 V. The efficacy of AC was evaluated. Results Current drain in the AC on group, AC off with optimized programming or nominal output was (14.33±2.84) mA, (16.74±2.75) mA and (18.4±2.44) mA, respectively (AC on or AC off with optimized programming vs. nominal output, P〈0.01). Estimated longevity was significantly extended by AC on when compared with nominal setting [(103±27) months, (80±24) months, P〈0.01). Furthermore, compared with the optimized programming, AC extends the longevity when the pacing threshold is higher than 1 V. Conclusion AC could significantly prolong pacemaker longevity; especially in the patient with high pacing threshold.
出处 《Chinese Medical Journal》 SCIE CAS CSCD 2006年第11期925-929,共5页 中华医学杂志(英文版)
关键词 AUTOCAPTURE current drain LONGEVITY pulse generator autocapture current drain longevity pulse generator
  • 相关文献

同被引文献40

  • 1王立群,郭继鸿,许原,赵京.起搏器自动夺获功能中备用脉冲发放情况的临床观察[J].临床心电学杂志,2004,13(3):172-175. 被引量:7
  • 2周军,陈玉华,顾锡华,张小忆,朱燕,徐芒华.心脏起搏器自动阈值夺获功能对使用寿命的影响[J].上海交通大学学报(医学版),2006,26(4):433-435. 被引量:1
  • 3钱剑安,顾刚,方祖祥.延长起搏器电池寿命的程控和计算方法[J].中国心脏起搏与心电生理杂志,1996,10(3):163-164. 被引量:7
  • 4Preston TA, Fletcher RD, Lucchesi BR, et aL Changes in myocardialthreshold : physiologic and pharmacologic factors in patients withimplanted pacemakers[ J]. Am Heart, 1967,74:235.
  • 5耿仁义,朱中林,华伟.实用心脏起撙技术[M].北京:人民军医出版社,2004.39-40.
  • 6Izzet E, Ahmet A, Erten O, et al. Long-term follow-up of pacemakers with an autoeapture pacing system[J ]. Jpn Heart,2002,43: 631.
  • 7Luria D, Gurevitz O, Bar Lev D, et al. Use of automatic threshold tracking function with non-low polarization leads: risk for algorithm malfunction[JJ. PACE,2004,27(4) :453.
  • 8Johannes S, Bernd N,Ewald H, et al. Acute performance evaluation of a new ventricular automatic capture algorithm [J ]. Europace, 2006,8:65.
  • 9Sperzel J, Pitschner HF, Schwarz T, et al. Automatic capture verification in ICD lead systems using intracardiac ventricular evoked response and reduced coupling capacitance [ J ]. Europace,2003,5 : 83.
  • 10Nurnberg J-H, Abdul-Khaliq H, Ewert P, et al. Antibradycardia pacing in patients with congenital heart disease: experience with automatic threshold determination and output regulation (AutocaptureTM [ J ]. Europace ,2003,5 : 199.

引证文献4

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部