电化学电池测量碳饱和铁液中的硅含量 被引量:1

DETERMINATION OF SILICON CONTENT IN CABON-SATURATED MELTEN IRON WITH ELECTROCHEMICAL CELL
下载PDF
导出
摘要 实验室条件下,用MgO部分稳定的ZrO_2作固体电解质,配以SiO_2,基辅助电极研制成电化学硅测头,对碳饱和的铁液进行了电动势的测量。测量结果表明:硅测头进入铁液5~10s后可以获得稳定的电动势,在1723~1823K范围内、测量电动势值与热力学计算电动势值符合较好,电动势测量法和化学分析法两种方法所得硅含量值仅相差±0.03%。该电化学硅测头不用取样,应答时间短,适合现场测量。 Laboratory EMFs measurement was conducted in molten Fe + C(sat)+Si system using ZrO2(MgO) solid electrolyte equipped with a new auxiliary electrode SiO2.The results showed that a stable EMF measurement was obtained after immersio of the developed silicon probe in molten Fe within 5 to 10s. In the range of 1723 and 1823K, the measured EMFs value corresponds with thermo-dynamics calculation value. The difference of measured silicon content with the EMF method and chemical analysis is only ±0.03 %. They are in good agreement. Due to the rapid response and accuracy of the silicon sensor, it is applicable in site
作者 贾成科
出处 《矿冶》 CAS 1996年第2期72-77,共6页 Mining And Metallurgy
关键词 电化学 电化学硅测头 硅含量 碳饱和 铁液 Silicon sensor Auxiliary electrode Electrochemical sensor