摘要 为探讨适合免疫电化学传感器检测克伦特罗的反应体系,本文采用单酶(葡萄糖氧化酶)体系和双酶(葡萄糖氧化酶和辣根过氧化物酶)体系进行了对比,结果在双酶反应体系下该传感器检测克伦特罗的灵敏度大约是单酶体系下的2倍,所得标准曲线对应关系良好,响应时间为200s。由此可知,双酶体系更灵敏,更适合于免疫生物传感器法检测克伦特罗。 In order to find a good reaction condition for detecting clenbuterol by the immune-electrochemical sensor, Single enzyme(glucose oxidase) and bienzyme(glucose oxidase and horseradish peroxidase) were used respectively. The results showed that the responsivity of the immune-electrochemical sensor in bienzyme condition was more sensitive than in single enzyme condition by two times or so. The standard curve of detecting clenbuterol by immune-electrochemical sensor in bienzyme condition was good, and response time was 200 seconds. But the standard curve of detecting clenbuterol in single enzyme condition was unavailable. Thereby, using bienzyme to detect clenbuterol by the immune-electrochemical sensor is more suitable.
出处 《上海交通大学学报(农业科学版)》 2006年第3期290-292,320,共4页 Journal of Shanghai Jiaotong University(Agricultural Science)
基金 上海市科技兴农重点攻关资助项目(农攻字第2002-20052)
关键词 单酶体系 双酶体系 克伦特罗 免疫生物传感器 single enzyme bienzyme clenbuterol immune-electrochemical sensor
  • 相关文献

参考文献7

二级参考文献29

  • 1金利通,刘海鹰,方禹之.双酶电极测定血清中抗坏血酸的研究[J].分析化学,1993,21(5):584-586. 被引量:3
  • 2邓家祺,张占恩.电聚高分子膜固定化酶生物传感器及其进展[J].分析科学学报,1995,11(4):71-76. 被引量:2
  • 3方道斌,吕鸣祥,张杰,陈昆明.人绒毛膜促性腺素(HCG)高分子生物活性膜的研制及其在HCG测定中的应用[J].中国生物医学工程学报,1995,14(1):1-6. 被引量:2
  • 4黄玉贤,曹继伟,孟淑珍,潘长宏,白虹,李晓波,王齐,牛健英.牛奶中过氧化氢含量测定方法研究报告[J].黑龙江畜牧科技,1997(2):11-13. 被引量:3
  • 5[2]Tatsuma T. Okawa Y, Watanabe T. Enzyme monolayer- and bilayer-modified Tin oxide electrodes for the determination of hydrogen peroxide and glucose [J ]. Anal. Chem., 1989, 61:2352-2355
  • 6[3]Tatsuma T. Watanabe T.Oxidase/peroxidase bilayer-modified electrodes as sensors for lactate,pyruvate,cholesterol and uric acid[J]. Anal. Chim. Acta. 1991, 242: 85-89.
  • 7[4]Garguilo M G. Huynh N, Proctor A, Michael A C. Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymer[J]. Anal. Chem., 1993, (65): 523-528
  • 8[5]Kulys J, Schmid R D. Mediatorless peroxidase electrode and preparation of bienzyme sensors[J]. Bioelectrochem. Bioenerg..1990, (24): 305-311.
  • 9[6]Wollenberger U, Bogdanovskaya V, Bobrin S, Scheller F, Tarasevich M.Enzyme electrodes using bioelectrocatalytic reduction of hydrogen peroxide[J]. Anal. Lett., 1990, (23): 1795-1808.
  • 10[7]Tatsuma T, Watanabe T and Watanabe T. Electrochemical characterization of polypyrrole bienzyme electrodes with glucose oxidase and peroxidase[J]. J. Electroanal. Chem.,1993,(356): 245-253.