摘要 建立了一个在含铀、钚的硝酸体系中测定99Tc的液体闪烁分析法。研究了取样体积、闪烁液用量、硝酸加入量、铀加入量、钚加入量等因素对99Tc测定的影响。此外还对用2,6-二甲基吡啶从碱性介质中分离纯化99Tc,以及自TBP中用CCl4稀释、用水反萃99Tc进行了研究。给出了用2,6-二甲基吡啶萃取-液闪测量99Tc的操作程序。此方法测定结果的单值相对标准偏差为0.6%。用该程序分析了各种工艺实验样品中99Tc含量,获得了满意的结果。 The determination of ̄(99)Tc in a system of UO2(NO3)2 -Pu(NO3)4 and HNO3 by a liquid scintillation counting is developed.The effects of sample volume,amount of scintillation cocktail,nitric acid, uranium and plutonium on the determination of 99Tc have been investigated.The isolation and purification of 99Tc using 2,6-dimethyl pyridine extraction from alkaline medium followed the stripping of 99Tc from 30%TBP-kerosene loaded with  ̄(99)Tc using CCl4 as diluent have also been studied.A determination procedure of  ̄(99)Tc by the liquid scintillation counting with 2,6-dimethyl pyridine extraction is recommended.The relative standard deviation for the determination of  ̄99Tc using this procedure is 0.6%. The procedure has been adapted to the samples containing uranium,plutonium and  ̄99Tc. The experimental results show that the analytical procedure for determining ̄(99)Tc is satisfactory.
出处 《核化学与放射化学》 CAS CSCD 北大核心 1996年第3期181-186,共6页 Journal of Nuclear and Radiochemistry
关键词 锝99 二甲基吡啶 液体闪烁计数法 Technetium-99 2,6-dimethly pyridine Liquid scintillation counting
  • 相关文献

参考文献6

二级参考文献6

  • 1张丕禄,原子能科学技术,1989年,23卷,4期
  • 2张绪立,裂变产物分析,1985年
  • 3张绪立,原子能科学技术,1976年,1期,101页
  • 4张绪立,原子能科学技术,1976年,2期,169页
  • 5张绪立,原子能科学技术,1976年,1期,53页
  • 6张绪立,原子能科学技术,1975年,1期,24页

共引文献6

同被引文献85

引证文献9

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部