摘要 本文报道为完成国际计量学会(CIPM)化学计量工作组(WGofMetrologyinChemicalAnalysis)组织的IDMS国际合作研究建立的Fe的测量方法。浓缩的 ̄57Fe溶液浓度用天然丰质的Fe标准溶液作为稀释剂用IDMS标定,然后用它作稀释剂,测量CIPM溶液Ⅱ中Fe。同其他国家提供的数据相比,本方法测量结果最佳. In this paper the method for determining Fe in the CIPM solution Ⅱ is described for the first interlaboratory study of the CIMP Working Group on Metrology in Chemical Analysis. The concentration of enriched isotope solution of 57Fe was certified with the standard solution of Fe as spike by IDMS. Then the content of Fe in the CIPM solution Ⅱ was determined with certified enriched isotopic solution as spike. The measurement result shows that the content of Fe in the CIPM solution Ⅱ is 32.10±0.11(μg.g-1). This result as compared with other interlaboratiory values is the best.
作者 赵墨田 王军
出处 《质谱学报》 EI CAS CSCD 1996年第3期1-5,共5页 Journal of Chinese Mass Spectrometry Society
关键词 IDMS 稀释剂 质谱 同位素 isotope dilution mass spectrometry international coordinate study iron