摘要 本文研究了以4-甲基伞形酮磷酸酯(4-MUP)为底物测定碱性磷酸酶(ALP)活性的高灵敏荧光法及其应用于人血清IgG的含量测定.通过纯化4-MUP,优化分析条件,使方法的灵敏度有较大提高,实用性也得到改善,测定ALP的线性范围为1.7×10-5~1.7×10-8IU/mL,检出限为4.0×10-9IU/mL,本法已成功地应用于血清样品ALP的测定.作为一个例子,通过测定免疫标记物HuIgG-ALP的活性,从而测定了IgG的含量,HuIgG的检出限为2. A highly sensitive fluorometric assay of alkaline phosphate(ALP) and its application to immunoassay are described. 4 Methylumbelliferyl phosphate(4 MUP) was investigated as fluorogetic substrate for ALP. By purifying the 4 MUP and optimizing the test conditions, the sensitivity was greatly improved. The linear range of ALP is 1.7×10 -5 -6.8×10 -8 IU/mL. The method has been applied successfully to the determination of ALP in human serum. As an example, the determination of human IgG was performed. The detection limit for human IgG is 2.48×10 -8 mg/mL.
出处 《分析科学学报》 CAS CSCD 1996年第3期206-209,共4页 Journal of Analytical Science
基金 国家自然科学基金资助课题
关键词 荧光法 磷酸酶 免疫分析 标记物 人血清 MUP Fluorometry, Alkaline phosphatase, 4 Methylumbelliferyl phosphate, Immunoassay