介绍了增安型高压电动机绝缘系统局部放电的基本形式及产生机理,提出了预防措施,并对国标中关于局部放电的检测与IEC标准的相关部分进行了比较。
This article introduces the fundamental mode and mechanism of production of partial discharge to the insulation system of increased safe high - voltage, and put forth the preventive measures to the partial discharge. Furthermore, the author makes comparison of the testing on partial charge between the relevant national or industrial standards and IEC 60079 - 7.
出处
《电气防爆》
2006年第2期13-17,共5页
Electric Explosion Protection
关键词
增安型
高压绝缘
局部放电
防爆检测
increased safe, high - tension insulation, partial discharge, testing on explosion protection performance