摘要 介绍了接地电池的组成及作用,通过现场试验数据,证实了接地电池对管/地电位测量会产生误差,对恒电位仪的输出会产生干扰,且较小的内阻会导致电流的流失。同时指出了在地下水较丰富的地区,不宜安装接地电池。 This paper introduces the constitution and function of electrolytic grounding cell. The field experimental data demonstrates that the measuring errors of pipe/soil potential produce and the interference of output values of potentiostat occur by the electrolytic grounding cell, and very small-scale internal resistance will result in the current loss. The authors consider that the electrolytic grounding cell is not suitable for installing in rich subterranean water region.
出处 《油气储运》 CAS 北大核心 2006年第6期27-30,共4页 Oil & Gas Storage and Transportation
关键词 长输管道 接地电池 阴极保护 影响 long distance pipeline,electrolytic grounding cell,cathodic protection system