摘要 污垢在换热器表面的沉积会大大降低其传热效率。结合某厂实例,采用水质分析、灼烧分析、等离子体发射光谱、扫描电子显微镜等分析手段分别对冷却水水质、污垢、淤泥、微生物等的特性进行了分析。结果表明,冷却水携带淤泥是该厂冷却水系统换热器表面污垢形成的主要原因。因此建议:(1)直排式冷却水系统的日常水质监测应增加淤泥监测项目;(2)冷却水取水口应与水底保持足够距离。 The fouling deposition on surface of the heat exchanger can tremendously reduce the heat transfer efficiency of said exchanger,hence,it is very important to diagnose the causes of fouling formation.Combined with the actual example in one power plant,many analyses,such as water quality analysis,ignition analysis,plasma transmitted spectrum,and scanning electron microscopy etc.,have been carried out,to analyse the quality of cooling water,and properties in aspects of fouling,silt,and microorganism respectively.The results show that the silt carried in cooling water of the said plant is the main cause of fouling formation on the surface of heat exchanger in cooling water system.Hence,it is recommended as in the foollowing:(1) the silt should be regarded as a special item in daily quality monitoring process of the direct discharging type cooling water system;(2) the cooling water intake port should be kept enough distance from the bottom of water supply reservoir.
出处 《热力发电》 CAS 北大核心 2006年第5期55-58,共4页 Thermal Power Generation
关键词 冷却水 换热器 污垢 淤泥 水库 cooling water heat exchanger fouling silt water reservoir
  • 相关文献

参考文献4

二级参考文献3

  • 1周本省.工业水处理技术[M].北京:化学工业出版社,1998..
  • 2项成林 等.工业水处理技术问答及常用数据[M].北京:化学工业出版社,1997..
  • 3尹慧,李冬梅,李永平.声波在界面上的反射和透射系数[J].曲阜师范大学学报(自然科学版),2000,26(3):59-60. 被引量:2

共引文献40

同被引文献14

  • 1张海林,杨善让,王恭,徐志明,王建国.凝汽器污垢实时在线监测与优化管理[J].热力发电,2005,34(4):11-14. 被引量:4
  • 2Khor S L, Sun D D, Liu Y, et al. Biofouling develop- ment and rejection enhancement in long SRT MF membrane bioreaetor[J]. Process Biochemistry, 2007, 42(12) :1641-1648.
  • 3Melo L F, Bott T R. Biofouling in water systems[J]. Experimental Thermal and F1 uid Science, 1997,14 (4) :375-381.
  • 4Bott T R. Fouling of heat exchangers [M].Nether- lands:Elsevier Science B V, 1995.
  • 5Ndpoles-Rivera F, Bin-Mahfouz A, Jim6nez-Guti6rrez A, et al. An MINLP model for biofouling control in seawater-cooled facilities [J]. Computers ~ Chemical Engineering, 2012,37 : 163-1 71.
  • 6Boxler C, Augustin W, Scholl S. Composition of milk fouling deposition in a plate heat exchanger under pulsed flow conditions[J]. Journal of Food Engineer- ing,2014,121:1-8.
  • 7Eguia E, Trueba A, Rio-Calonge B, et al. Biofilm con- trol in tubular heat exchangers refrigerated by seawa- ter using flow inversion physical treatrnent[J].Inter- national Biodeterioration ~ Biodegradation, 2008, 62 (2) :79-87.
  • 8王晓璐,郭淑青,董向元.污垢对350MW机组运行影响的试验分析[J].热力发电,2008,37(4):76-78. 被引量:5
  • 9姜建国,杨祥良,孙荣峰,许敏,杨靖.600MW直冷机组空冷凝汽器冷却管束污垢热阻对热经济性的影响[J].热力发电,2008,37(12):9-12. 被引量:6
  • 10王洋,张晓健,陈雨乔,陆品品,陈超.给水管网管壁铁细菌生长特性模拟及控制对策研究[J].环境科学,2009,30(11):3293-3299. 被引量:16