期刊文献+

BACTEC9050自动血培养仪的临床应用 被引量:1

Clinical Application and Evaluation of BACTEC9050 Automated Blood Culture System
下载PDF
导出
摘要 目的评价BACTEC 9050自动血培养仪的临床应用情况。方法分析2年来自动血培养仪检测的阳性率、阳性报警时间、菌种鉴定及临床分析。结果检测2 424份血培养标本,分离出328株菌,总阳性率为13.5%(328/2 424),其中革兰阴性菌167株(50.91%,167/328),阳性菌112株(34.15%,112/328),真菌49株(14.94%,49/328)。分离率居前三位的细菌是大肠埃希菌(22.86%),金黄色葡萄球菌和肺炎克雷白菌(10.36%),白色念珠菌(7.32%)。在全部328例阳性瓶中,24 h阳性报告率为51.36%,48及72 h阳性率分别为78.5%、92.3%。结论BACTEC 9050自动血培养仪对肠杆菌、葡萄球菌及真菌具有较好的检测能力。 Objective To evaluate the clinical application of BACTEC 9050 automated blood culture system. Methods Two thousand four hundred and twenty-four blood samples were detected by BACTEC 9050 automated blood culture system. The types of microorganisms recovered and the positive rate were also analyzed. Results Three hundred and thirty-one samples were positive with alarm and 328 strains were isolated. Positive rate was 13.5%, of which, 167 (50.91% ) were gram negative bacteria, 112 (34.15 % ) were gram negative cocci, 49 (14.94 % ) were fungus. The most common pathogens were E. coli, Staphylococcus aureaus, K. pneumoniae and Candida alblcans. The cumulative positive rate was 51.36 % within 24h, 78.5 % within 48 h and 92.3 % within 72 h. Conclusion BACTEC 9050 automated blood culture system is applicable in clinical use especially for aerogens, Staphylococcus and fungus.
出处 《同济大学学报(医学版)》 CAS 2006年第3期77-79,共3页 Journal of Tongji University(Medical Science)
关键词 自动化血培养 BACTEC 9050 菌血症 规范操作 BACTEC 9050 automated blood culture system bacteremia standardization
  • 相关文献

参考文献5

二级参考文献14

  • 1花天放.中心静脉导管性败血症[J].上海医学,1989,12(1):55-57. 被引量:10
  • 2[1]Adal KA,Farr BM. Central venous catheter-related infections:a review[J]. Nutrition, 1996,12: 208-213
  • 3[2]Dobbins BM, Catton JA, Kite P, et al. Each lumen is a potential source of central venous catheter-related bloodstream infection [J]. Crit Care Med,2003,31:1688-1690
  • 4[5]Mermel LA, Farr BM, Sherertz RJ, et al. Guidelines for the management of intravascular catheter-related infections[J]. J Intraven Nurs,2001,24:180-205
  • 5[6]Marvaso A. Central venous catheter-related infections[J]. Infez Med,2000,8 : 202-210
  • 6[7]Moonens F, el Alami S, van Gossum A, et al. Usefulness of gram staining of blood collected from total parenteral nutrition catheter for rapid diagnosis of catheter-related sepsis[J]. J Clin Microbiol, 1994,32:1578-1579
  • 7[8]Viale P,Pagani L, Petrosillo N, et al. Antibiotic lock-technique for the treatment of catheter-related bloodstream infections[J]. J Chemother,2003,15:152-156
  • 8生物梅里埃.血液培养技术问题回报[C].第5届VITEK学术会论文集,1994,21:22.
  • 9Morello JA, Leitch C, Nitz S, et al. Detection of bacteremia by Difco ESP blood culture system[J]. J Clin Microbiol, 1994, 32:811-818.
  • 10周庭银,陆建平,陈育贵.血液培养中150株细菌结果分析[C].全国医学检验学术论文汇编,1982,31-32.