摘要 分析比较38例正常糖调节及39例新诊断2型糖尿病个体动态血糖监测系统(CGMs)显示的平均血糖水平、日内平均血糖波动幅度(MAGE)及日间血糖平均绝对差(MODD)。结果提示,血糖波动幅度应成为评价2型糖尿病患者血糖控制是否达标的重要参数。 Thirty-eight individuals with normal glucose regulation and thirty-nine newly diagnosed type 2 diabetic patients were observed by continuous glucose monitoring system (CGMS) for three days. The mean blood glucose, mean amplitude of glycemic excursions ( MAGE), and absolute means of daily differences (MODD) were calculated in each subject. The results suggested that the amplitude of glycemic excursions revealed by CGMS could be used to evaluate the quality of glycemic control in type 2 diabetic patients.
出处 《中华内分泌代谢杂志》 CAS CSCD 北大核心 2006年第3期286-288,共3页 Chinese Journal of Endocrinology and Metabolism
基金 上海市糖尿病临床医学中心建设基金(ZX02A13) 上海科学技术发展基金(024032)
关键词 糖尿病 2型 血糖波动 动态血糖监测系统 Diabetes mellitus, type 2 Glycemic excursion Continuous glucose monitoring system
  • 相关文献

参考文献6

  • 1喻明,周健,项坤三,陆惠娟,马晓静,陆蔚.动态监测糖耐量正常者血糖水平的漂移变化[J].中华医学杂志,2004,84(21):1788-1790. 被引量:50
  • 2Service FJ, Molnar GD, Rosevear JW, et al. Mean amplitude of glycemic excursions, a measure of diabetic instability. Diabetes, 1970,19:644-655.
  • 3Molnar GD, Taylor WF, Ho MM. Day-to-day variation of continuously monitored glycaemia: a further measure of diabetic instability. Diabetologia, 1972,8:342-348.
  • 4Selam JL. How to measure glycemic instability? Diabetes Metab, 2000,26:148-151.
  • 5Muggeo M, Verlato G, Bonora E, et al. Long-term instability of fasting plasma glucose, a novel predictor of cardiovascular mortality in elderly patients with non-insulin-dependent diabetes mellitus: the Verona Diabetes Study. Circulation, 1997,96:1750-1754.
  • 6Risso A, Mercuri F, Quagliaro L, et al. Intermittent high glucose enhances apoptosis in human umbilical vein endothelial cells in culture.Am J Physiol Endocrinol Metab, 2001,281 :E924-E930.

二级参考文献11

  • 1American Diabetes Association. Clinical practice recommendations. Diabetes Care,2001, 24(Suppl.1): 5-24.
  • 2World Health Organization. Definition, diagnosis and classification of diabetes mellitus and its complications. Report of a WHO consultation, Part 1: Diagnosis and classification of diabetes mellitus. Geneva: WHO, 1999.
  • 3Mastrototaro J. The MiniMed continuous glucose monitoring system(CGMS). J Pediatr Endocriol Metab, 1999,12:751-758.
  • 4Gross TM, Bode BW, Einhorn D, et al. Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use. Diabetes Technol Ther,2000,2:49-56.
  • 5Cheyne EH, Cavan DA, Kerr D. Performance of a continuous glucose monitoring system during controlled hypoglycaemia in healthy volunteers. Diabetes Technol Ther,2002,4:607-613.
  • 6Boyne MS, Silver DM, Kaplan J, et al. Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes, 2003, 52:2790-2794.
  • 7Kaufman FR, Gibson LC, Halvorson M, et al. A pilot study of the continuous glucose monitoring system. Diabetes Care, 2001,24:2030-2034.
  • 8Boland E, Monsod T, Delucia M, et al. Limitations of conventional methods of self-monitoring of blood glucose. Diabetes Care,2001,24: 1858-1862.
  • 9Rohlfing CL, Wiedmeyer HM, Litter RR, et al. Defining the relationship between plasma glucose and HbA1c. Diabetes Care, 2002,25:275-278.
  • 10Hay LC, Wilmshurst EG, Fulcher G. Unrecognized hypo- and hyperglycemia in well-controlled patients with type 2 diabetes mellitus:the results of continuous glucose monitoring. Diabetes Technol Ther,2003,5:19-26.

共引文献49

同被引文献1091

引证文献177

二级引证文献1632

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部