期刊文献+

直丝弓滑动技术与正畸摩擦力研究现状 被引量:1

下载PDF
导出
出处 《川北医学院学报》 CAS 2006年第3期288-290,共3页 Journal of North Sichuan Medical College
  • 相关文献

参考文献18

  • 1Adrerew LF,The straight wire appliance[J].Clin,Orthod,1976,10(10):99
  • 2Mclaughlin R P,Bennett J C.The transition form standard edgewise to preadjusted appliance systems[J].Clin.orthod.1989,23(2):142
  • 3曾祥龙,许天民.系统化正畸治疗技[M].天津:天津科技翻译出版公司,2002,13-21
  • 4Moore M M,Harrington E,Rock W P.Factors affecting friction in the pre-adjusted appliance[J].European Journal of Orthodontics,2004,26(6):579-583
  • 5Hemingway R,Williams R L,Hunt J A,et al.The influence of bracket type on the force delivery of Ni-Ti archwires[J].The European Journal of Orthodontics,2001,23(3):233-241
  • 6Michelberger DJ,Eadie RL.The friction and wear patterns of orthodontic brackets and archwi res in the dry state[J].Am J Orthod Dentofac,2000,118(5):662-674
  • 7Cash A,Curtis R,Garrigia-Majo D,et al.A comparative study of the static and kinetic frictional resistance of titanium molybdenum alloy archwires in stainless steel brackets[J].The European Journal of Orthodontics,2004,26(1):105-111
  • 8Banaie F,Parikakis K,Moberg S,etal.The variable anchorage straight wire technique compared with the straight wire technique in deep overbite correction[J].European Journal of Orthodontics,2005,27(2):180-185
  • 9Frank CA,Nikolai RJ.A comparative study of frictional resistance between orthodontic bracket and archwire~[J].Am orthod Dentofac Orthop,1980,78(6):593-609
  • 10Neumann P,Bourauel C,Jager A.Corrosion and permanent fracture resistance of coated and conventional orthodontic wires[J].Journal of Materials Science-Materials in Medicine,2002,13(2):141-147

同被引文献18

  • 1Thorstenson GA,Kusy RP.Effects of ligation type and method on the resistance to sliding of novel orthodontic brackets with second-order angulation in the dry and wet states.Angle Orthod.2003;73:418-430.
  • 2Baccetti T,Franchi L.Friction produced by types of elastomeric ligatures in treatment mechanics with the preadjusted appliance.Angle Orthod.2006;76:211-216.
  • 3Franchi L,Baccetti T.Forces released during alignment with a preadjusted appliance with different types of elastomeric ligatures.Am J Orthod Dentofacial Orthop.2006;129:687-690.
  • 4Turnbull NR,Birnie DJ.Treatment efficiency of conventional vs self-ligating brackets:effects of archwire size and material.Am J Orthod Dentofacial Orthop.2007;131:395-399.
  • 5Harradine NW.Self-ligating brackets and treatment efficiency.Clin Orthod Res.2001;4:220-227.
  • 6Tecco S,Festa F,Caputi S,et al.Friction of conventional and self-ligating brackets using a 10 bracket model.Angle Orthod.2005;75:1041-1045.
  • 7Harradine NW.Self-ligating brackets and treatment efficiency.Clin Orthod Res.2001;4(4):220-227.
  • 8Harradine NW,Birnie DJ.The clinical use of Activa self-liga2ting brackets.Am J Orthod Dentofacial Orthop.1996;109(3):319-328.
  • 9Eberting JJ,Straja SR,Tuncay OC,Treatment time,outcome,and patient satisfaction comparisons of Damon and conventionalbrackets.Clin Orthod Res.2001;4(4):228-234.
  • 10Pizzoni L,Ravnholt G,Melsen B.Frictional forces related to self-ligating brackets.Eur J Orthod.1998;20(3):283-291.

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部