期刊文献+

氢化物发生-ICP-AES法测定饮料中的痕量砷和汞 被引量:2

DETERMINATION OF TRACE ARSENIC AND MERCURY IN DRINK BY HYDRIDE GENERATION ICP AES
下载PDF
导出
摘要 研究了连续式氢化物发生-感耦等离子体原子发射光谱法测定饮料中As和Hg的适宜条件,可以用较低的功率(1.1kW)获得稳定的分析信号.待测元素含量0.05~0.1mg/L时,RSD小于5%(10次测定);加标回收率87%~100%. A method for simultaneous determination of trace concentrations of As and Hg in drink have been investigated by continuous flow mode hydride generation and inductively coupled plasma atomic emission spectrometry.The influence of operating conditions on the result of analysis is discussed.The proposed method is sensitive,accurate and easy to operate.The relative standard deviation is less than 5% if the concentration is 0.05~0.1 mg/L.The recovery of standard addition is 87%~100%.
出处 《四川大学学报(自然科学版)》 CAS CSCD 1996年第4期419-423,共5页 Journal of Sichuan University(Natural Science Edition)
关键词 氢化物发生 ICP-AES法 饮料 Arsenic,Mercury,hydride generation,inductively coupled plasma atomic emission spectrometry
  • 相关文献

参考文献2

二级参考文献3

  • 1张卓勇,分析化学,1987年,15卷,9期,801页
  • 2郑毅,分析化学,1987年,15卷,11期,966页
  • 3滕藤,溶剂萃取化学,1981年

共引文献6

同被引文献99

引证文献2

二级引证文献43