用电测法对湖南江垭水电站溢流坝段中孔、表孔泄洪闸门进行了静、动力特性和局部开启单独及联合泄洪时的振动响应观测;评定了闸门安全性,并为江垭水电站制定闸门安全操作规程和竣工安全鉴定提供了技术资料。
The prototype observation about the crest sluice gates and the mid-orifice sluice gates of Jiangya hydropower station is described. The static and dynamic performance and the response of the gates (single and cooperating) under partially opened discharing condition are measured by electrometry. The safety factors of the gates are assessed for final appraisal, and the observation result is used as technical basis for laying down operating instruction for them.
出处
《湖北水力发电》
2006年第2期58-61,共4页
Hubei Water Power
关键词
江垭水电站
闸门
原型观测