期刊文献+

Hard X-Ray PHA System on the HT-7 Tokamak 被引量:1

Hard X-Ray PHA System on the HT-7 Tokamak
下载PDF
导出
摘要 A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA). The hard X-ray diagnostics consists of a vertical X-ray detector array (CdTe) and a horizontal X-ray detector array (NaI). The hard X-ray diagnostics can provide the profile of power deposition and the distribution function of fast electron during radio frequency (RF) current drive. The MCA system is the electronic part of the PHA system, which has been modularized and linked to PC through LAN. Each module of MCA can connect with 8 X-ray detectors. The embedded Ethernet adapter in the MCA module makes the data communication between PC and MCA very convenient. A computer can control several modules of MCA through certain software and a hub. The RAM in MCA can store 1024 or more spectra for each detector and therefore the PHA system can be applied in the long pulse discharge of several minutes. A new hard X-ray pulse-height analysis (PHA) system has been established on HT-7 tokamak for long pulse steady-state operation. This PHA system consists of hard X-ray diagnostics and multi-channel analysers (MCA). The hard X-ray diagnostics consists of a vertical X-ray detector array (CdTe) and a horizontal X-ray detector array (NaI). The hard X-ray diagnostics can provide the profile of power deposition and the distribution function of fast electron during radio frequency (RF) current drive. The MCA system is the electronic part of the PHA system, which has been modularized and linked to PC through LAN. Each module of MCA can connect with 8 X-ray detectors. The embedded Ethernet adapter in the MCA module makes the data communication between PC and MCA very convenient. A computer can control several modules of MCA through certain software and a hub. The RAM in MCA can store 1024 or more spectra for each detector and therefore the PHA system can be applied in the long pulse discharge of several minutes.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2006年第3期261-264,共4页 等离子体科学和技术(英文版)
基金 supported by National Nature Science Foundation of China (No. 10235010)
关键词 PHA TOKAMAK hard X-ray MCA lower hybrid current driven (LHCD) PHA, tokamak, hard X-ray, MCA, lower hybrid current driven (LHCD)
  • 相关文献

参考文献7

  • 1Kuang G, LHCD Group of ASIPP. A MW LHCD system and its first operation on HT-7 superconducting tokamak. 24th EPS Conference on Controlled Fusion and Plasma Physics, Berchtesgaden, Germany, 9 - 14 June 1997. Europhys. Conf. Abstr., 1997, 21A, Ⅰ: 457-460
  • 2Kuang G, Liu Y, Shan J, et al. Nucl. Fusion, 1999,39:1769
  • 3Li J, Bao Y, Zhao Y, et al. Plasma Phys. Control.Fusion, 2001, 43:1227
  • 4Zhao Y, Li J, Ruo J, et al. Plasma Phys. Control.Fusion, 2001, 43:343
  • 5Shi Y, Wan B, Li B, et al. Chinese Physics, 2001,10:134
  • 6Peysson Y, Imbeaux F. Rev. Sci. Instrum., 1999, 70:1
  • 7Liang Y F, Yin X J, Fang Z S, et al. Fusion Engineering and Design, 1997, 34:201

同被引文献4