摘要
根据多年来的工程实践经验,提出了一级反渗透装置后续“两级混床”实际使用中存在的问题,并通过不同水源,从理论上计算后证明,全新的“阴床+混床”作为一级反渗透装置后续化学除盐工艺,相比以往常用及传统的反渗透装置后续化学除盐工艺,具有最低的设备投资,最少的酸碱耗量及废水排放量;其适用水质范围之广,是反渗透装置后续“两级混床”工艺所不能相比拟的。
Based on the experience fi'om project implementation for some years, the present authors put forward the existing problem of one stage reverse osmosis followed by "two mixed bed in series". Through theoretical calculation for the application in various water sources, the new system of one stage reverse osmosis followed by "anion plus mixed bed" is proved to be more advanced for pure water preparation than traditional technique with post treatment with one stage reverse osmosis in terms of cost for equipment investment, acidic and caustic volume, and volume of waste water drainage. Thus, in comparing with" two mixed bed in series", the new system can be applicable to a wider range of water resources.
出处
《水处理技术》
CAS
CSCD
北大核心
2006年第7期1-7,共7页
Technology of Water Treatment
关键词
一级反渗透
后续脱碳器(如果需要)
阴床加混床
混床阳阴树脂比例
one stage reverse osmosis
post degasifier
anion exchanger and mixed bed, the volume ratio of cation to anion in mixed bed