期刊文献+

多层螺旋CT与超声对比定量评估左心功能 被引量:20

Multislice CT versus echocardiography for quantitative assessment of left ventricular function
下载PDF
导出
摘要 目的通过16层螺旋CT(MSCT)与超声左心容积数据的对比,初步探讨MSCT定量评估左心功能在心容积数据方面的准确性及可行性。方法选择22例8h内同时进行了MSCT冠状动脉造影及超声心动图检查的患者,对比MSCT自动测量与手工测量值的相关性,MSCT自动测量与超声测量值的相关性。结果MSCT左心容积各组数据自动与手动测量结果相关性高(r>0.98,P>0.05);MSCT自动测量与超声测量结果相关性良好(r>0.90,P>0.05)。结论MSCT冠状动脉造影检查所获得的自动与手动左心容积数据准确性高,可用于临床诊断。 Objective To explore the accuracy and feasibility of 16-slice spiral CT (MSCT) in evaluating the left ventricular function through comparing left ventricular volume data obtained by MSCT with data gained by echocardiography. Methods Twenty-two patiens were performed CT coronary angiography and echocardiography subsequently in eight hours. The correlativity of two groups of data obtained through manual survey and auto survey, as well as correlativity of data gained through MSCT and echocardiography were tested separately. Results The data of left ventricular function tested with manual survey and that of auto survey were highly correlated (r〉0.98, P〉0.05). The data of MSCT auto survey and that of echocardiography were also highly correlated (r〉0.90, P〉0.05). Conclusion The data of left ventricular function meas- ured with auto survey and manual survey of CT coronary angiography were accurate, which can be used in clinical diagnosis.
出处 《中国医学影像技术》 CSCD 北大核心 2006年第6期906-908,共3页 Chinese Journal of Medical Imaging Technology
关键词 心室功能 体层摄影术 X线计算机 超声心动描记术 Ventricular function, left Tomography, X-ray computed Echocardiography
  • 相关文献

参考文献7

  • 1Buck T,Hunold P,Wentz KU,et al.Tomographic three-dimensional echocardiographic with unrestricted selection of chamber size and systolic function in patients with left ventricular aneurysm:comparison to magnetic resonance imaging,cine ventriculography,and two-dimendional echocardiography[J].Circulation,1997,96(7):4286-4297.
  • 2Hibberd MG,Chuang ML,Beaudin RA,et al.Accuracy of three dimensional echocardiographic with unrestricted selection of imaging planes for measurement of left ventricular volumes and ejection fraction[J].Am Heart,2000,140(2):469-475.
  • 3Hundley W G,Morgan T M,Neagle C M,et al.Magneic resonace imaging determination of cardiac prognosis[J].Circulation,2002,29(18):2328-2333.
  • 4Walter H,Karen S,Bernd J W,et al.Assessment of global left ventricular function comparison with cardiac multidetector-row computed tomography with angiocardiography[J].Comput Assist Tomogr,2005,29 (3):373-381.
  • 5Thomas S,Konstantin P,Christoph U H,et al.Assessment of left ventricular parameters using 16-MDCT and new software for endocardial and epicardial border dilineation[J].AJR,2005,184(3):765-7731.
  • 6Andreas H M,Ralf K,Marcus K,et al.Sixteen-slice spiral CT versus MR imaging for the assessment of left ventricular function in acute myocardial infarcion[J].Eur Radiol,2005,15 (1):714-720.
  • 7李佩玲,徐克,黎庶,王强.心率对16层螺旋CT冠状动脉造影图像质量的影响及其重建相位窗的优选[J].中国介入影像与治疗学,2006,3(1):18-22. 被引量:22

二级参考文献7

  • 1[1]Nieman K,Oudkerk M,Rensing BJ,et al.Coronary angiography with multi-slice computed tomography.Lancet,2001,357(9256):599-603.
  • 2[2]Achenbach S,Giesler T,Ropers D,et al.Detection of coronary artery stenoses by contrast-enhanced,retrospectively electrocardiographically-gated,multislice spiral computed tomography.Circulation,2001,103(21):2535-2538.
  • 3[3]Hamoir XL,Flohr T,Hamoir V,et al.Coronary arteries:assessment of image quality and optimal reconstruction window in retrospective ECG-gated multislice CT at 375-ms gantry rotation time.Eur Radiol,2005,15(2):296-304.
  • 4[4]Nieman K,Rensing BJ,Van Geuns RJ,et al.Non-invasive coronary angiography with multislice spiral computed tomography:impact of heart rate.Heart,2002,88(5):470-474.
  • 5[5]Hong C,Becker CR,Huber A,et al.ECG-gated reconstructed multi-detector row CT coronary angiography:effect of varying trigger delay on image quality.Radiology,2001,220(3):712-717.
  • 6[6]Kopp AF,Schroeder S,Kuettner A,et al.Coronary arteries:retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window.Radiology,2001,221(3):683-688.
  • 7[7]Achenbach S,Ulzheimer S,Baum U,et al.Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT.Circulation,2000,102(23):2823-2828.

共引文献21

同被引文献175

引证文献20

二级引证文献82

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部