运用变压器经济运行技术,结合某矿110 kV变电所的实际情况,在安全用电的基础上,推算出变压器经济运行区间及变压器分接头档位的经济区,改进了原来变压器投切的随意性和变压器分接头选择的不经济性,变压器进入经济运行模式。
This paper adopted the technology of transformer economy operation, calculated transformer economy operation section and its tap economy operation section based on safe electricity combining with 110 kV substation instance of a mine, modified previously transformer operated on randomly and transformer tap selected diseconomy, transformer has been operated on economy operation mode.
出处
《有色冶金节能》
2006年第3期33-35,共3页
Energy Saving of Nonferrous Metallurgy
关键词
变压器
负载率
优化选择
经济运行
transformer
load ratio
optimized selection
economy operation