一种消除维生素C干扰的血清尿酸检测方法 被引量:1

A method for eliminating the interference of vitamin C in the determination of serum uric acid
下载PDF
导出
摘要 目的 利用4-羟基-2,2,6,6-四甲基-1-氧-哌啶(AAQ-2)作为维生素C(Vit C)的熄灭剂,建立双试剂终点法测定血清尿酸(UA),以消除VitC在UA测定中的干扰。方法 采用双试剂终点法测定UA。结果 方法重复性:日内相对标准差(RSD)为1.50%,1.37%,日间RSD为1.55%、1.40%;平均回收率:99.34%;本法线性可达50~1550μmol/L。结论 本方法可消除血清中高浓度VitC对UA测定的干扰,且适用于自动分析仪。 Objective Using 4-hydroxy-2,2,6,6-tetramethyl-1-piperidinyloxy free radical( ascorbic acid quencher-2,AAQ-2) as quencher of vitamin C( Vit C), to establish an end point method of double reagent for determining serum uric acid( UA), to eliminate the interference of Vit C in determining serum UA. Methods The level of serum UA was determined by end point method of double reagent. Results The assay precision was satisfactory. Within-run relativestandard deviation(RSD) were 1.50% and 1.37%, between-run RSD were 1.55% and 1.40% respectively. The average rate of recovery was 99.34%. The assay linearity was 50-1 550 μmol/L. Conclusions The method can eliminated the interference of high concentration Vit C in determining serum UA,and be used in automatic analysis.
出处 《检验医学》 CAS 北大核心 2006年第4期337-339,共3页 Laboratory Medicine
关键词 尿酸 维生素C 4-羟基-2 2 6 6-四甲基-1-氧-哌啶 Uric acid Vitamin C 4-hydroxy-2,2,6,6-tetramcthyl-1-piperidinyloxy free radical
  • 相关文献

参考文献3

  • 1林其燧 文庆成.临床化学诊断方法大全[M].北京:北京大学出版社,1990.488.
  • 2万唐,熊声贺.维生素C对某些生化检测项目的干扰[J].中国卫生检验杂志,2001,11(3):309-310. 被引量:3
  • 3Kayamori Y,Katayama Y,Urata T.Nonenzymatic elimination of ascorbic acid in clinical samples[J].Clin Biochem,2000,33:25-29.