摘要 医学图像融合就是来自相同或不同成像方式的医学图像之间的空间配准和叠加,这些图像经过必要的变换处理,使它们的空间位置、空间坐标达到匹配,叠加后获得互补信息及增加信息量,把有价值的生理、生化信息与精确的解剖结构结合在一起,给临床医学诊断提供更加全面和准确的资料。 Medical image amalgamation means interspace registration and superposition between the medical image, which comes from uniform or different ways of formation of imagines. Once these images have been undertaken indispensable counterchange and proceeds, their interspace position and spatial coordinate can be matching. After superposition, information will be complementary and enlarge its capacity so as to combine the valuable physiological, biochemical information and accurate anatomical structure, which provides more comprehensive and precise data for clinical and medical diagnosis.
出处 《华夏医学》 CAS 2006年第3期620-622,共3页 Acta Medicinae Sinica
关键词 医学图像融合 特征提取 图像配准 medical image amalgamation characteristics distill image registration
  • 相关文献

参考文献15

  • 1KOVACEVIC N,LOBAUGH N J,BRONSKILL M J,et al.A robust method for extraction and automatic segmentation of brain images[J].Neuroimage,2002,17(3):1087-1010.
  • 2WELLMER J,VON QERTZEN J,SCHALLER C,et al.Digital photography and 3D MRI-based multimodal imaging for individualized planning of resective neocortical epilepsy surgery[J].Epilepsia,2002,43(12):1543-1550.
  • 3MALISON R T,MILLER E G,GREENE R,et al.Computer-assisted coregistration of multislice SPECT and MR brain images by fixed external fuducials[J].J Comput Assist Tomogr,1993,17(6):952-960.
  • 4MOUNTZ J M,ZHANG B,LIU H G,et al.A reference method for correlation of anatomic and functional brain images:validation and clinical application[J].Semin Nucl Med,1994,24(4):256-271.
  • 5KAGADIS G C,DELIBASIS K K,MATSOPOULOS G K,el al.A comparative study of surface and volume based techniques for the automatic registration between CT and SPECT brain images[J].Med Phys,2002,29(2):201-213.
  • 6EBED S,KANNO I,FULTON R R,et al.Automated interstudy image registration technique for SPECT and PET[J].J Nucl Med,1996,37(1):137-145.
  • 7JUNCK L,MOEN J G,HUTCHINS G D,et al.Correlation methods for the centering,rotation,and alignment of functional brain images[J].J Nucl Med,1990,31(7):1220-1226.
  • 8HILL D L,HAWKES D J,CLEESON M J,et al.Accurate frameless registration of MR and CT images of the head:application in planning surgery and radiation therapy[J].Radiology,1994,191(2):447-457.
  • 9MAES F,COLLIGNON A,VANDERMEULEN D,et al.Multimodality image registration by maximization of mutual imformation[J].IEEE Trans Med Imaging,1997,16(2):187-198.
  • 10WOODS R P,DAPRETTO M,SICOTTE N L,et al.Creation and use of a talairach compatible atlas for accurate,automated,nonlinear intersubject registration,and analysis of functional imaging data[J].Hum Brain Mapp,1999,8(2-3):73-79.

二级参考文献28

  • 1Erdi YE, Rosenzweig K, Erdi AK, et al. Radiotherapy treatment planning for patients with non-small cell lung cancer using positron emission tomography (PET). Radiother Oncol, 2002, 62: 51-60.
  • 2ICRU. ICRU report 50. Prescribing, recording, and reporting photon beam therapy. Washington: ICRU, 1993.
  • 3Rasch C, Barillot I, Remeijer P, et al. Definition of the prostate in CT and MRI: a multi-observer study. Int J Radiat Biol Phys, 1998,43: 57-66.
  • 4Daisne JF,Sibomana M,Bol A,et al. Evaluation of a multimodality image (CT, MRI and PET) coregistration procedure on phantom and head and neck cancer patients: accuracy, reproducibility and consistency.Radiother Oncol, 2003,69: 237-245.
  • 5Nehmeh SA, Erdi YE, Ling CC, et al. Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer. Med Phys,2002, 29: 366-371.
  • 6Gupta NC, Tamim WJ, Graeber GG. Mediastinal lymph node sampling following positron emission tomography with fluorodeoxyglucose imaging in lung cancer staging. Chest,2001,120: 521-527.
  • 7Roman MR, Rossleigh MA, Angelides S, et al. Staging and managing lung tumor using F-18FDG coincidence detection. Clin Nucl Med, 2001,26: 383-388.
  • 8Townsend DW, Beyer TA. Combined PET/CT scanner: the path to true image fusion. Br J Radiol, 2002,75: S24-30.
  • 9Nakamoto Y, Osman M, Cohade C, et al. PET/CT: comparison of quantitative tracer uptake between germanium and CT transmission attenuation-corrected images. J Nucl,2002,43:1137-1143.
  • 10Nishioka T, Shiga T, Shirato H, et al. Image fusion between 18FDG-PET and MRI/CT for radiotherapy planning of oropharyngeal and nasopharyngeal carcinomas, Int J Radiat Oncol Biol Phys, 2002, 53:1051-1057.

共引文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部