摘要
采用L-半胱氨酸为预还原剂,建立了断续流动进样氢化物发生-原子荧光光谱法同时测定纺织品中微量砷和锑的方法。并确定了仪器的最佳工作条件,考察了介质和载流酸度、硼氢化钠浓度、L-半胱氨酸浓度和载流流速的影响以及共存元素的干扰情况。方法简便、快速。在选定的测定条件下,砷和锑的检出限分别为0.35和0.22μg·L^-1,相对标准偏差分别为1.3%和2.8%,回收率分别为93.6%~98.4%和92.2%~103.6%。
A method for the simultaneous determination of trace arsenic and antimony in textile by intermittent flow-hydride generation-atomic fluorescence spectrometry with L-cysteine as a prereducer was developed. The optimal instrument condition was established. The influence factors such as the acidity of sample solution and carrier liquid, the concentrations of KBH4 and Lcysteine, the flow rate of carrier, and the interference of coexistent elements were investigated. The method was convenient and rapid. Under the optimal condition, the detection limits were 0. 35 and 0. 22μg·L^-1 , the relative standard deviations were 1.3% and 2. 8%, and the recoveries were in the ranges of 93. 6%-98. 4% and 92. 2%-103. 6% for As and Sb respectively.
出处
《光谱学与光谱分析》
SCIE
EI
CAS
CSCD
北大核心
2006年第7期1352-1355,共4页
Spectroscopy and Spectral Analysis
基金
福建出入境检验检疫局科研基金资助
关键词
L-半胱氨酸
断续流动
氢化物发生-原子荧光光谱法
纺织品
砷
锑
L-cysteine
Intermittent-flow
Hydride generation-atomic fluorescence spectrometry
Textile
Arsenic
Antimony