期刊文献+

严重心力衰竭症状和除颤器不当电击风险之间的关系

Relation of advanced heart failure symptoms to risk of inappropriate defibrillator shocks
下载PDF
导出
摘要 Inappropriate implantable cardioverter- defibrillator(ICD)shocks continue to be a major source of distress to patients and a drain on the health care system. Expanding indications for ICD implantation include a large portion of patients with heart failure. This study investigated the relation between inappropriate ICD shocks and the severity of heart failure symptoms. Predictors of the time to first inappropriate ICD therapy were investigated in 230 consecutive patients implanted in 2001 and 2002. Thirty- two patients received 42 inappropriate shocks during a median follow- up of 501 days. Inappropriate shocks were due to atrial fibrillation(AF) or tachycardia(n=31), other supraventricular tachycardias(n=6), sinus tachycardia(n=3), and noise or double counting(n=2). The time to first inappropriate ICD shock was earliest in patients with advanced classes of heart failure(1- and 2- year shock- free survival of 79% and 70% for patients in New York Heart Association [NYHA] class III or IV vs 92% and 88% for patients in NYHA class I or II, respectively, p=0.02). After correcting for age, gender, the presence of coronary artery disease, the presence of AF, the use of β blockers, and indication for ICD implantation in a Cox regression model, advanced heart failure(NYHA class III or IV) remained an independent predictor of first inappropriate ICD shocks(hazard ratio 2.7, p=0.01). Other predictors of the time to first inappropriate ICD shock included the presence of AF as the baseline rhythm at the time of the ICD implantation and the absence of coronary disease. In conclusion, inappropriate ICD shocks are predominantly due to AF. Advanced heart failure is an independent predictor of the time to first inappropriate ICD shocks. The effect of ICD programming and antiarrhythmic drug therapy on the incidence of inappropriate shocks deserves further investigation. Inappropriate implantable cardioverter-defibrillator(ICD) shocks continue to be a major source of distress to patients and a drain on the health care system. Expanding indications for ICD implantation include a large portion of patients with heart failure. This study investigated the relation between inappropriate ICD shocks and the severity of heart failure symptoms. Predictors of the time to first inappropilate ICD therapy were investigated in 230 consecutive patients implanted in 2001 and 2002. Thirty-two patients received 42 inappropriate shocks during a median follow-up of 501 days. Inappropriate shocks were due to atrial fibilllation(AF) or tachycardia(n = 31), other supraventricular tachycardias (n = 6), sinus tachycardia (n = 3), and noise or double counting(n =2) . The time to first inappropriate ICD shock was earliest in patients with advanced classes of heart failure ( 1- and 2-year shock-free survival of 79% and 70% for patients in New York Heart Association [NYHA] class Ⅲ or Ⅳ vs 92% and 88% for patients in NYHA class Ⅰ or Ⅱ, respectively, p = 0. 02) . After correcting for age, gender, the presence of coronary artery disease, the presence of AF, the use of β blockers, and indication for ICD implantation in a Cox regression model, advanced heart failure(NYHA class Ⅲ or Ⅳ) remained an independent predictor of first inappropriate ICD shocks(hazard ratio 2.7, p = 0. 01 ).
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部