提出一种加固型的热线式流速传感器,它由一根较粗的绝缘棒和贴在其上的铂丝组成;并给出了与该结构相适应的新的计算流速经验公式.风洞实验证明,对于加固后的热线流速传感器,新的计算公式比King氏公式有较高的计算精度.在0~20m/s的单量程范围内,测量误差从用King氏公式时的0.65m/s减小到0.14m/s.
Reinforced hot wire probes are described.The new probe is a cylincal rod on which a platinum wire is fixed. A new equation Which relates the probe output and flow velocity is presented. Experiments in the wind tunnel show that the new equation resultS in a better measurement than is given by King's law.The measurement error is decreased from 0.65m/s(by King's law) to 0.14m/s in the range of 0-20m/s.
出处
《北京理工大学学报》
EI
CAS
CSCD
1996年第4期385-388,共4页