期刊文献+

CT和MR肝脏灌注成像技术及其临床应用 被引量:2

CT and MR perfusion imaging of the liver:techniques and clinical applications
原文传递
导出
摘要 近年来随着CT、MR功能成像研究的发展,国内外有不少学者尝试使用CT、MR肝脏灌注成像评价肝脏功能及肝脏病变的血液动力学特征。综述了近来国内外CT、MR灌注成像在肝脏评价中的应用现状,重点是图像分析方法及临床应用。 In recent years the functional imaging techniques of CT and MR including perfusion imaging have developed fast. Some studies are attempting to evaluate the hepatic function and the hemodynamic characteristics of the hepatic lesions by using CT or MR perfusion imaging. The purpose of this article is to review the recent studies of the applications of CT and MR perfusion imaging to the evaluation of the liver. The main topics are imaging analysis and clinical applications.
作者 顾爱华
出处 《国际放射医学核医学杂志》 2006年第3期188-192,共5页 International Journal of Radiation Medicine and Nuclear Medicine
关键词 体层摄影术 X线计算机 磁共振成像 灌注成像 Tomography X-rays, computed Magnetic resonance imaging Liver Perfusion imaging
  • 相关文献

参考文献23

  • 1Axel L. Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis. Radiology, 1980, 137: 679-686.
  • 2Gulberg V, Haag K, Rossle M, et al. Hepatic arterial buffer response in patients with advanced cirrhosis. Hepatology, 2002,35(3): 630-634.
  • 3Tsushima Y, Funabasama S, Sanada S, et al. Development of perfusion CT software for personal computers. Acad Radiol, 2002,9(8): 922-926.
  • 4Annet L, Materne R, Danse E, et al. Hepatic flow parameters measured with MR imaging and Doppler US: correlations with degree of cirrhosis and portal hypertension. Radiology, 2003, 229 (2):409-414.
  • 5Ichikawa T, Arbab AS, Araki T, et al. Perfusion MR imaging with a superparamagnetic iron oxide using T2-weighted and susceptibility-sensitive echoplanar sequences: evaluation of tumor vascularity in hepatocellular carcinoma. AJR, 1999, 173(1): 207-213.
  • 6Materne R, Smith AM, Peeters F, et al. Assessment of hepatic perfusion parameters with dynamic MRI. Magn Reson Med, 2002,47(1): 135-142.
  • 7Van Beers BE, Leconte I, MaternetR, et al. Hepatic perfusion parameters in chronic liver disease: dynamic CT measurements correlated with disease severity. AJR, 2001, 176(3): 667-673.
  • 8Peters AM, Brown J, Hartnell GG, et al. Non-invasive measurement of renal blood flow with 99mTc DTPA: comparison with radiolabelled microspheres. Cardiovasc Res, 1987, 21(11): 830-834.
  • 9Tsushima Y, Blomley MJ, Kusano S, et al. Measuring portal venous perfusion with contrast-enhanced CT: comparison of direct and indirect methods. Acad Radiol, 2002, 9(3): 276-282.
  • 10Blomley MJ, Coulden R, Dawson P, et al. Liver perfusion studied with uhrafast CT. J Comput Assist Tomogr, 1995, 19(3): 424-433.

同被引文献79

引证文献2

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部