期刊文献+

胎儿血氧饱和度监测在预测胎儿酸中毒中的应用 被引量:1

原文传递
导出
摘要 目的研究胎儿血氧饱和度(FSO2)预测胎儿酸中毒的阈值及准确性。方法200212-200406对广东省人民医院及青海红十字会医院的226例产妇在宫口开大3cm以上者行FSO2监测及电子胎儿监护仪监护,应用受试者工作特征曲线评估FSO2阈值;研究将30%作为FSO2阈值,评估其预测胎儿酸中毒的准确性。结果第二产程FSO2较第一产程下降,二者均值差异有显著性;脐动脉血气与FSO2呈相关性;将30%作为FSO2阈值,预测胎儿宫内缺氧的敏感性、特异性、阳性预测值、阴性预测值及准确性分别为88.9%、96.8%、84.2%、97.6%、95.6%。结论将30%作为FSO2的阈值是适宜的;FSO2可提高诊断胎儿宫内酸中毒的准确性。
出处 《中国实用妇科与产科杂志》 CAS CSCD 北大核心 2006年第8期606-608,共3页 Chinese Journal of Practical Gynecology and Obstetrics
基金 广东省医学科学技术研究基金资助(项目编号:A2002023)
  • 相关文献

参考文献10

  • 1Boehm FH.Intrapartum fetal heart rate monitoring[J].Obstet Gynecol Clin North Am,1999,26(4):623-639.
  • 2Dildy GA,Van den Berg PP,Katz M,et al.Intrapartum fetal pulse oximetry:fetal oxygen saturation trends during labor and relation to delivery outcome[J].Am J Obstet Gynecol,1994,171(3):679-684.
  • 3韩凤珍,边旭明,盖铭英,刘俊涛,杨剑秋.胎儿血氧饱和度监测在产程中的应用[J].中国医学科学院学报,2003,25(6):685-688. 被引量:5
  • 4Chua S,Yeong SM,Razvi K,et al.Fetal oxygen saturation during labor[J].Br J Obstet Gynecol,1997,104(9):1080-1083.
  • 5Thorp JA,Rushing RS.Umbilical cord blood gas analysis[J].Obstet Gynecol Clin North Am,1999,26(4):695-709.
  • 6Seelbach-Gobel B,Riedl T.Reliability of fetal pulse oximetry for the detection of fetal acidosis[J].Z Geburtshilfe Neonatol,2005,209(2):43-50.
  • 7Garite TJ,Dildy GA,McNamara H,et al.A multicenter controlled trial of fetal pulse oximetry in the intrapartum management of nonreassuring fetal heart rate patterns[J].Am J Obstet Gynecol,2000,183:1049-1058.
  • 8Bakr AF,Al-Abd M,Lcarbour T.Fetal pulse oximetry and neonatal outcome:a study in a developing country[J].J Perinatol,2005,25(12):759-762.
  • 9Dildy GA,Thorp JA,Yeast JD,et al.The relationship between oxygen saturation and pH in umbilical blood:implication for intrapartum fetal oxygen saturation monitoring[J].Am J Obstet Gynecol,1996,175:682-689.
  • 10Salamalekis E,Vitoratos N,Loghis C,et al.Evaluation of non-reassuring fetal heart rate patterns with fetal pulse oximetry combined with vibratory acoustic stimulation[J].J Maternal-fetal Neonat Med,2003,13:110-114.

二级参考文献24

  • 1[1]Dildy GA. The physiologic and medical rationale for intrapartum fetal monitoring. Biomed Instrum Technol, 1999, 33(2): 143-151
  • 2[2]Dildy GA. The future of intrapartum fetal pulse oximetry.Curr Opin Obstet Gynecol, 2001, 13(2):133-136
  • 3[3]Kuhnert M, Seelbach-Goebel B, Butterwegge M. Predictive agreement between the fetal arterial oxygen saturation and fetal scalp pH: results of the German multicenter study.Am J Obstet Gynecol, 1998, 178(2):330-335
  • 4[4]Carbonne B, Langer B, Goffinet F, et al. Multicenter study on the clinical value of fetal pulse oximetry. Ⅱ. Compared predictive values of pulse oximetry and fetal blood analysis.The French Study Group on Fetal Pulse Oximetry. Am J Obstet Gynecol, 1997, 177(3):593-598
  • 5[5]Hasenburg A, Bauerle M, Waterman D, et al. European experience with a novel noninvasive sensor for intra-amniotic or extra-amniotic evaluation of fetal oxygen saturation. J Soc Gynecol Investig, 2003, 10(6):347-351
  • 6[6]Yam J, Chua S, Arulkumaran S. Intrapartum fetal pulse oximetry. Part 2: Clinical application. Obstet Gynecol Smv,2000, 55(3):173-183
  • 7[7]Siristatidis C, Salamalekis E, Vitoratos N, et al. Intrapartum surveillance of IUGR fetuses with cardiotocography and fetal pulse oximetry. Biol Neonate, 2003, 83(3):162-165
  • 8[8]Thorp JA, Rushing RS. Umbilical cord blood gas analysis.Obstet Gynecol Clin North Am, 1999, 26(4):695-709
  • 9[9]McNamara H, Chung DC, Lifford R, et al. Do fetal pulse oximetry readings at delivery correlate with cord blood oxygenation and acidaemia? Br J Obstet Gynaecol, 1992,99(9):735-738
  • 10[10]Langer B, Boudier E, Haddad J, et al. Fetal pulse oximetry during labor of 62 patients. Fetal Diagn Ther,1996, 11(1):37-45

共引文献4

同被引文献4

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部