摘要
本文介绍了在江苏玻璃厂主厂房保护性控爆拆除工程中,同时存在楼上炸楼楼内炸楼、地坪1.5m以上拆除和三面楼段保留的微距离定向爆破的特点。通过精心设计,合理采取技术措施,以及精心施工,达到了设计的预期效果,取得了综合处理的成功经验。
The 'protective operation of minute-gap blast-oriented.design at Jiangsu Glass works 11as been introduced. The design involves simultaneously one building blast on another building terrace, one building blast insid another building and one demolition 1 .5 meters above the building ground, with the three requested sections of the workshop kept intact Many challenging problems encountered in the project have been resolved and desired results have been obtained. Successful experience has been achieved from elaborate design and operation, precise adoption of blast data and tech n iques.
出处
《爆破》
CSCD
1996年第1期16-20,共5页
Blasting
关键词
拆除
爆破
高层建筑
厂房
demolition, blast-oriented, height of blast, broken pile,recoil.