摘要 采用信号分析和软件的方法,实现医用核磁共振成像过程中的信号可视化,获得反映人体组织特性的T1、T2、共振频率值,以及反映信号强度的FID、回波等曲线,有助于进行临床核磁共振应用分析和核磁共振成像原理的教学。 By software and signal analysis, visualization of medical NMR signals becomes possible. The T1, T2 resonance frequency value reflecting human tissue characteristics, and the FID, echo wave as well as other curves reflecting the intensity of signals, can contribute a lot to the teaching of the applied analysis of clinical NMR and MRI principles.
出处 《医疗卫生装备》 CAS 2006年第7期76-77,共2页 Chinese Medical Equipment Journal
关键词 核磁共振 自由感应衰减信号 驰豫信号 核磁共振成像 NMR FID signal relaxation time MRI
  • 相关文献

参考文献4

二级参考文献12

  • 1邱建峰,于兹喜,李月卿,王昌元,徐惠.数字乳腺X线照片CAD中可疑密度区域的自动分割(英文)[J].泰山医学院学报,2005,26(2):136-139. 被引量:4
  • 2张仲礼 周辉 等.近代物理实验[M].长春:东北师范大学出版社,1992..
  • 3徐玉书 许静 等.自旋回波法测理驰豫时间[J].物理实验,1984,4(3):99-102.
  • 4[2]李月卿等.医学影像成像原理.北京:人民卫生出版社,2003
  • 5Yuan-hsiang Chang. Knowledge-based computer-aid detection of masses on digitized mammograms: a preliminary assessment, Med[J]. Phys, 2001,28(4):455-461.
  • 6Georgia D. tourassi, Application of the mutual information criteron for feature selection in computer-aid diagnosis, Med[J]. Phys, 2001,28(12):2349-2402.
  • 7Lefebvre F, Berger G, Laugier P. Automatic detection of the boundary of the calcaneus from ultrasound parametric images using an active contour model[J]. clinical assessment, IEEE Trans Medical Imaging, 1998, 17(1):45-52.
  • 8李祥林.[D].泰安:泰山医学院,2005.
  • 9Zhong Xue, AI-Snake: an affine-inwariant deformable contour model for object matching[J]. Image and vision computing, 2002,20(8),77-84.
  • 10Kenneth R. Castleman, Prentice-Hall International, Inc[M]. Digital Image Processing, 2001.

共引文献28

同被引文献10

  • 1张平寅,钱英.磁共振成像技术探讨[J].医疗卫生装备,2005,26(2):19-21. 被引量:9
  • 2王灌忠,沈钧康,张彩元.信噪比在MR图像质量控制中的作用[J].医学影像学杂志,2003,13(11):879-881. 被引量:13
  • 3邱建峰,王鹏程,鲁雯,刘玉,林海洋.核磁共振实验设计探讨[J].中国医学装备,2005,2(12):30-32. 被引量:16
  • 4Price RR,Axel L,Morgan T,et al.Quality assurance methods and phantoms for magnetic resonance imaging[R].Report of AAPM Nuclear Magnetic.Resonance Task Group.No.1.Med Phys,1990,17:287-295.
  • 5Och JG,Clarke GD,Sobol WT,et al.Acceptance testing of magnetic resonance imaging systems[R].Report of AAPM Nuclear Magnetic Resonance Task Group.No.6.Med Phys,1992,19:217-229.
  • 6Hashemi RH,Bradley WG.MRI:the basics[M].New York:Williams,1997:167-174.
  • 7Stumpf D A,Alksne J F, Annegers J F,et al. Neurofibromatosis. NIH consensus development conference statement [J]. Archives of Neurology, 1988,45(5) :575-578.
  • 8Baser M E, R Evans D G, Gutmann D H. Neur ofibromatosis 2 [J]. Current Opinion of Neurology, 2003,16(1) :27-35.
  • 9Babovic S,Bite U,Karnes P S,et al.Liposuction : a less invasive surgical method of debulking plexiform neurofibromas [J]. Dermatologic Surgery, 2005,29 (7) : 785-789.
  • 10康立丽,卢广文,余晓锷,杨绍洲.MRI扫描参数与信噪比关系的实验研究[J].中华放射学杂志,2003,27(3):225-227. 被引量:32