摘要
在考虑了中能重离子反应出射中子天空反射效应的基础上,以4×1011ions/s、100MeV/u12C+Cu(厚靶)反应为例,计算出重离子物理实验小区需设置的顶部屏蔽混凝土厚度d=1.1m.
Based on considering the skyshine and the distribution of neutrons emitted from the reaction of 100MeV/u 12 C+Cu, the concrete shielding thickness of overhead shielding of the small experimental area in the physical experimental hall is calculated, which would be about 1.1m.
关键词
中能重离子反应
实验小区
天空反射中子
顶部屏蔽
intermediate energy heavy ion reaction small experimental area skyshine neutron overhead shielding