摘要
介绍了江苏省城区220~110kV变电所的环境现状调查结果,从环境保护的角度对江苏省220~110kV变电所典型设计进行了评述,得出城市高压变电所存在的主要环境问题是噪声的结论,从而提出噪声超标原因、治理措施以及变电所典型设计的建议。
The paper introduces the environmental status survey results of 220- 110 kV urban substations in Jiangsu province, reviews the typical designs of 220-110 kV substations from the aspect of environmental protection, draws the conclusion that noise problem is the main environmental problem existing in urban substations and thus presents the cause of noise out of specification, control measures as well as suggestions on typical design of substations.
出处
《江苏电机工程》
2006年第4期4-6,共3页
Jiangsu Electrical Engineering
关键词
城市变电所
噪声
电磁辐射
典型设计
urban substation
noise
electromagnetic radiation
typical design