摘要
针对江苏仪征化纤股份有限公司热电厂5号除碳器自2002年投运以来除碳效果差的现象,通过流量试验、风压试验和内部检查分析了原因,给出了除碳器改造措施和改造后的效果,生产数据表明:该改造产生良好的经济效益。
One of the carbon dioxide cleaner did not run effectively in the thermal power plant of Yizheng Chemical Fibre Company since 2002. The cause of the problem was studied through a series of tests, including flow, wind pressure tests and interior inspection. Based on it, the modification was carried out and it proved to have made good economic effects.
出处
《江苏电机工程》
2006年第4期10-11,共2页
Jiangsu Electrical Engineering
关键词
热电厂
除碳器
填料
技改措施
thermal power plant
carbon dioxide cleaner
filler
modification