就E-502冷却器安装镁牺牲阳极产生的阻力降进行了计算,指出处于最佳保护效果时,产生的阻力降小于原阻力降的1/1000,不影响运行工况。
The fluid resistance produced by setting Magnesium sacrifice anodes in the cooler E-502 was calculated, which indicates that the fluid resistance was less than 1/1000 of the original fluid resistance measured without setting any anodes in it while the best preservation and protection effect was reached up, so that, not showing any influence for the working conditions of cooler being protected.