介绍了万家寨水电厂调速器液压部分的结构及工作原理,分析了压油泵烧毁的原因,提出了防止压油泵烧毁的应对措施。
The article introduces the structure and working principles of hydrodynamic unit of the governor installed in wanjiazhai water power plant, analyses the cause why the force feed pump was burned down and puts forward the countermeasures against the burning down of the pump.